1. PCI/PCIe TFP Hardware
4. Wait for the TFP to set bit 0 of the ACK register. Do not begin writing another command to the
Input Area until this bit becomes set.
Windows example (uses bc635PCIcfg.exe GUI):
Set the Periodic rate output to 10KPPS and Synchronous Mode.
Select the Advanced Menu.
Use the Special Tab and the DP RAM selection from the menu list.
a. Offset 102 (input packet base address)
b. Value 14 (14 is the set periodic output command ID)
c. select the WRITE button
d. Offset 103
e. Value 1 (value of 1 here selects Synchronous Mode)
f. select the WRITE button
g. Offset 104
h. Value 0 (msb of n1 value)
i. select the WRITE button
j. Offset 105
k. Value a (lsb of n1 value set to decimal 10)
l. select the WRITE button
m. Offset 106
n. Value 0 (msb of n2 value)
o. select the WRITE button
p. Offset 107
q. Value a (lsb of n2 value set to decimal 10)
r. select the WRITE button
s. select the ACK button and the Periodic output will be set.
- 38 -