FITTED EQUIPMENT
93
TRUMA FAULT FINDING
SYMPTOM
CAUSE
RECTIFICATION
Gas operation
When switching on, the
heater does not operate.
When switching on, the
heater does not operate and
the red lamp lights up after
approx. 30 secs.
Heater operates for a
prolonged time and then the
red lamp lights up.
• No 12 V supply voltage.
• Window open.
• Cowl cover fitted.
• No gas supply.
• Incorrect gas pressure.
• Air in the gas supply.
• Over temperature
thermostat operated.
• Check the power supply
(operation voltage min. 10.5 V).
• Check the water heater fuse
(refer to mainanance “Fuses”).
• Close any windows above the
cowl.
• Remove cowl cover and / or
clear any obstruction.
• Check gas valves and gas
bottle.
• Check gas valves and gas
bottle.
• To unlock (and purge air),
switch off the appliance, wait 5
minutes, and switch on again.
• Check water content, refill if
required (close drain valve).
• To unlock, switch off the
appliance, wait 5 minutes, and
switch on again.
Electrical operation
When switching on, the
heater does not operate.
• No 230 V supply
voltage.
• Over temperature
thermostat operated.
• Too slow warm-up in
position 850 W
• Connect the motorhome to
the site supply and / or check
residual current circuit breaker.
• Check water content, refill if
required (close drain valve).
• The electrical heating element
is fitted with an excess
temperature cut-out. In event of
a fault, switch off at the control
panel, wait 10 minutes, then
switch on again.
• Please contact the Truma
Service.
Water supply
Water drips from the safety/
drain valve.
When opening the cold water
tap, hot water tap comes out.
• Water pressure to high.
• Hot water flows back
through the cold water
supply.
• Check water pressure (max. 2.8
bar), use a pressure reducer
when connected to central
water supply.
• Fit a no-return valve in the
cold water supply (refer to
installation instructions “Water
connection”).
If fault persists please contact the nearest Truma Service (see Truma Service Booklet or
www.truma.com).
Summary of Contents for Motorhomes 2013
Page 2: ...Motorhome Owner s Service and Warranty Handbook...
Page 6: ...4...
Page 16: ...WA RR A NT Y INF OR MATIO N 14...
Page 17: ...MO TOR HOME CO DE 15 MOTORHOME CODE Code of conduct 16 The Country code 18 The Coastal code 18...
Page 28: ...P RE PA RIN G F OR T H E R O A D 26...
Page 32: ...E N R OU TE 30...
Page 41: ...A RRIVA L AT SIT E 39 ARRIVAL AT SITE Positioning the motorhome 40...
Page 52: ...SE R VICE S 50 GAS SCHEMATIC Typical gas schematic drawing with water heater...
Page 64: ...SE R VICE S 62...
Page 167: ...F ITTE D E QU IP ME NT 165...
Page 182: ...F IT T E D E QU IP M E N T 180 SHOWER COLOUR REFERENCE...
Page 194: ...MA IN T E NA N CE 190...
Page 200: ...U SE FU L INF OR MATIO N 196...
Page 201: ...U SE F U L INF OR MAT ION 197...