2.3 Activating the System
The EC400 system has a shutdown feature
that should be used when the vehicle is in
storage or is not being used for long periods of
time. This allows the leisure electronics to be
turned off when not required to save battery
power. When in the off state the alarm and
tracking system supplies are still active, most
other supplies are turned off.
Before using the system please ensure the
shutdown switch is in the system on position
(button in).
2.4 Connecting to the Mains 230V supply
and Safety checks
For your safety it is IMPORTANT that you
follow these connections instructions each
time your Leisure Vehicle is connected to a
mains supply. This section assumes that the
system is complete and that a Leisure battery
has been installed (see 3.4).
A)
Ensure suitability of the Mains Supply
.
Your Leisure Vehicle should only be
connected to an approved supply that
meets the requirements of BS7671 or
relevant harmonised standards. In most
cases the site warden will hold information
regarding suitability of supply. If using a
generator you also need to comply with
the requirements / instructions supplied
with the generator.
Please note that some electronic
generators may not be compatible with
your leisure system. Further generator
operational information is contained
elsewhere in this manual.
B)
Switch the PSU internal Power
Converter OFF
. Locate the green
‘Charger’ power switch on the PSU and
ensure the switch is in the off position
(button out) before connection to the
mains supply.
C)
Connect the Hook-up Lead
. Firstly
connect the supplied hook-up lead
(orange cable with blue connectors) to the
Leisure Vehicle and then connect to the
mains supply.
D)
Check Residual Current Device
operation
. Locate the RCD within the
PSU and ensure the RCD is switched
on (lever in up position). Press the ‘Test’
button and confirm that the RCD turns
off (lever in down position). Switch the
RCD back to the on position (lever in up
position). If the test button failed to operate
the RCD see section 3.10.
E)
Check Miniature Circuit Breakers
.
Locate the MCB’s within the PSU
(adjacent to the RCD) and ensure they are
all in the on (up) position. If any MCB’s fail
to ‘latch’ in the on position
see section 3.10.
F)
Turn the PSU ON
. Locate the black
‘Shutdown’ button and ensure it is in the
on position (press button in). Locate the
green ‘Charger’ switch on the PSU and
turn to the on position (press button in).
The charger switch will illuminate when
turned on.
G)
Check correct Polarity
. Locate the
‘Reverse polarity’ indicator on the PSU
and ensure that the indicator is NOT
illuminated. If the indicator is illuminated
see section 3.10.
H)
Check operation of equipment
. It is
now safe to operate the 12v and 230v
equipment.
2.5 Control Panel - Component Layout
Depending on your type of vehicle (caravan
or motorhome) the control panel will vary in
specification.
Not all features are present in all vehicles.
Please refer to the following diagrams to
identify your control panel.
EC400 SERIES POWER SUPPLY SYSTEM
Summary of Contents for Motorhomes 2013
Page 2: ...Motorhome Owner s Service and Warranty Handbook...
Page 6: ...4...
Page 16: ...WA RR A NT Y INF OR MATIO N 14...
Page 17: ...MO TOR HOME CO DE 15 MOTORHOME CODE Code of conduct 16 The Country code 18 The Coastal code 18...
Page 28: ...P RE PA RIN G F OR T H E R O A D 26...
Page 32: ...E N R OU TE 30...
Page 41: ...A RRIVA L AT SIT E 39 ARRIVAL AT SITE Positioning the motorhome 40...
Page 52: ...SE R VICE S 50 GAS SCHEMATIC Typical gas schematic drawing with water heater...
Page 64: ...SE R VICE S 62...
Page 167: ...F ITTE D E QU IP ME NT 165...
Page 182: ...F IT T E D E QU IP M E N T 180 SHOWER COLOUR REFERENCE...
Page 194: ...MA IN T E NA N CE 190...
Page 200: ...U SE FU L INF OR MATIO N 196...
Page 201: ...U SE F U L INF OR MAT ION 197...