27
SplitMode
logger file splitting mode:
0
– no splitting
-1
– split after each measurement cycle
15
– split after each full 15 minutes of real time clock
30
– split after each full 30 minutes of real time clock
60
– split after each full hour of the real time
1440
– split at defined times
28..33
SplitTimeN
Six timestamp values of logger file splitting (only if SplitMode is
1440):
-1
– value is inactive
0..1439
– time in minutes (for example, 100 means 1:40 AM)
34
GpsLast30sSyncTime
time in seconds between start of measurement and last
synchronization of real time clock based on GPS signal:
-
Value 0FFFFh means that within 30 seconds before the
start of measurement, real-time clock synchronization did
not occur
-
The parameter says nothing about synchronizing the
real-time clock before 30 seconds prior to the
measurement start
35..36
MeasureStartTimeMs
measurement start time in milliseconds
37
SplitCycles
number of split measurement files (zero means infinity) - the
parameter is important if the duration of the measurement cycle
(IntTimeSec) is set to infinity; for finite measuring cycle times this
parameter is irrelevant (see: RepCycle)
…
reserved
Table B.1.8.
Measurement triggering parameters
Word
number
Name
Comment
0
0nn2Bh
2Bh = block identifier
0nnh = block length in words
1
TriggerMode
trigger mode:
0
– measurement without triggering
1
– positive slope (
Slope +
)
2
– negative slope (
Slope
–
)
3
– positive level trigger (
Level +
)
4
– negative level trigger (
Level
–
)
6
– positive gradient (
Grad +
)
7
– external pulse
2
TriggerSource
trigger source (parameter relevant only to modes in which triggering
is related to signal level):
0
– triggering RMS/Leq level from the first profile
-
Other remaining values
3
TriggerLevel
trigger threshold value in 0.01 dB format (parameter relevant only to
modes in which triggering is related to signal level)
4
TriggerGrad
trigger gradient value in 0.01 dB/ms format (parameter relevant only
to „Grad+” mode)
5
reserved
6
reserved
7
TriggerStep
trigger time check in 0.1ms format
…
reserved
Summary of Contents for SVAN 979
Page 272: ...272 SVAN 979 User Manual Appendixes 400 Hz 500 Hz 630 Hz 800 Hz 1000 Hz 1250 Hz ...
Page 273: ...273 SVAN 979 User Manual Appendixes 1600 Hz 2000 Hz 2240 Hz 2500 Hz 2800 Hz 3150 Hz ...
Page 274: ...274 SVAN 979 User Manual Appendixes 3550 Hz 4000 Hz 4500 Hz 5000 Hz 5600 Hz 6300 Hz ...
Page 275: ...275 SVAN 979 User Manual Appendixes 7100 Hz 8000 Hz 8500 Hz 9000 Hz 9500 Hz 10000 Hz ...
Page 312: ...312 SVAN 979 User Manual Appendixes Summary curve ...
Page 348: ...348 SVAN 979 User Manual Appendixes 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz ...
Page 349: ...349 SVAN 979 User Manual Appendixes 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz ...
Page 350: ...350 SVAN 979 User Manual Appendixes 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz ...
Page 351: ...351 SVAN 979 User Manual Appendixes 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz ...
Page 352: ...352 SVAN 979 User Manual Appendixes 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz ...
Page 370: ...370 SVAN 979 User Manual Appendixes O ring gasket locations inside ...