1J-8 Charging System:
• Install the generator cover (3) and tighten the
generator cover bolts.
WARNING
!
Be careful not to pinch the finger between the
generator cover and the crankcase.
• Route the CKP sensor and generator lead wire. Refer
to “Wiring Harness Routing Diagram in Section 9A
(Page 9A-3)”.
• Tighten the fuel pump mounting bolts to the specified
torque.
Tightening torque
Fuel pump mounting bolt (e): 10 N·m (1.0 kgf-m,
7.0 lb-ft)
• Adjust the reverse lock cable play. Refer to “Reverse
Lock Cable Play Inspection and Adjustment in Section
5B (Page 5B-1)”.
• After installing the removed parts, pour engine oil.
Refer to “Engine Oil and Filter Replacement in
Section 0B (Page 0B-11)”.
Regulator / Rectifier Inspection
B933H21A06005
Inspect the regulator/rectifier in the following procedures:
1) Turn the ignition switch OFF.
2) Disconnect the regulator/rectifier coupler (1) and remove the regulator/rectifier (2).
3
I933H11A0020-01
(e)
I933H11A0021-01
1
2
I933H11A0022-01
PartShark.com
877-999-5686
Summary of Contents for LT-Z400
Page 2: ...P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6 ...
Page 4: ...P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6 ...
Page 62: ...0C 9 Service Data P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6 ...
Page 296: ...1K 6 Exhaust System P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6 ...
Page 358: ...3A 18 Drive Chain Drive Train Drive Shaft P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6 ...
Page 408: ...4D 5 Parking Brake P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6 ...
Page 460: ...6B 13 Steering Handlebar P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6 ...
Page 490: ...P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6 ...
Page 491: ...P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6 ...