8.2
WEEKLY CHECK-UP
⇒
NOTE THAT THE FAN IS WORKING
⇒
CLEAR VENTILATION FILTER
⇒
NOTE TEMPERATURE ON TOUCH SCREEN
If the temperature in the hot zone has dropped significantly check
moisture, colour, smell, filling level of material inside cylinder and
airflow to and from cylinder. Add pellets/sawdust, empty cylinder,
clear ventilation and/or adjust settings accordingly.
⇒
INSPECT THE PROCESSED MATERIAL AND MAKE SURE THAT THE
MATERIAL IS NOT TOO WET OR DRY.
⇒
EMPTY BIN ON OUTLET IF NECESSARY
⇒
IF A BIOFILTER IS INSTALLED – EMPTY THE BIOFILTER USING THE
BALL VALVE.