3.26.3
CONFIGUARTION OF INFEED REVERSE FUNCTION
The function of the in-conveyor motor trying to reverse two
times if something gets stuck before sending an alarm can be
adjusted in this menu.
The frequency inverter setting is set using this menu. These
parameters may need adjusting to the quality of the food waste
material if the inverter gives this alarm when nothing is actually
blocking the in-conveyor or only gives this alarm when the
blockage is too tight.
The screen shows the actual current reading in % and the following parameters can be adjusted:
-
Threshold current limit in % = this setting gives the current in (%) relative to actual motor current
-
Delay time current = defines delay time prior to acitavtion of comparision of threshold current and
rated motor current.
-
Run time reverse = time for infeeder to run in reverese.
The values set at delivery can be found in ‘Machine Specification’.
If adjustments are necessary – contact your distributor for advice before proceeding.
3.27
FACTORY SETTINGS
The factory settings are only available for the manufacturer of the machine.
3.28
DOWNLOADING A NEW PROGRAM
Note that there are two programs that needs to be downloaded if both PLC and touchscreen should
be updated or rebooted. Programs are delivered in a Zip folder.
Do not use a MAC computer when extracting the files from the Zip folder as the files will not work
properly!
Take an empty USB stick and copy the files in the extracted folder to the USB stick.
The folders and files must be placed directly to the root folder of the USB stick.
Turn off the electical supply and put in the USB stick.
Turn on the electrical supply and wait until the questions on download of appears.
Answer yes on the TWO questions (one for touch screen program and one for PLC program)
Wait until the panel is rebooted.
NOTE! Toch panel program will load first.
Keep your eye on the screen and wait for the question: download PLC program? and answer
YES!
Enter all values in ‘Tools’ level from the machine specification as well as settings in ‘Operator’ level.