MAIN SWITCH, RESET BUTTON AND TOUCH SCREEN.
The machine is operated from the touch screen which is placed on the door of the electrical cabinet.
On the door of the electrical cabinet there is a main switch which must be locked out and tagged out
when the bolted covers are removed and the machine is maintained or serviced. When the main
switch on Big Hanna is turned on the fan starts automatically and the cylinder will start rotating after
minimum 30 minutes on its automatic cycle. The Big Hanna’s biological process require 24/7
operation and should never be turned off at the main switch unless it its serviced, repaired or taken
out of service.
The blue reset button (not incl. on all models) on the electrical cabinet has three modes:
Mode:
Status:
Dark blue/ Not lit up.
No alarm. Power to all motors.
Firm blue light.
Alarm is active. No power to any motors. Pressing the button will not reset the
machine – fault must be located and the source of the alarm must be
eliminated.
Flashing blue light.
Alarm is not active but button needs to be pressed in order to reset the
machine. No power to any motors.
1.
Touch screen
2.
Emergency stop button
3.
Reset button
4.
Main switch
5.
USB Socket