10.5
ALARM – CYLINDER MOTOR - FUSE OR RELAY TRIPPED
Reset the fuse/relay inside the electrical cabinet.
- Check incoming electricity (one phase could be missing).
- Make sure the cylinder is not overloaded - check the level of material
inside the cylinder through the inspection doors – see below.
- Inspect the sprocket and chain for wear. See 9.2.10
- Problem can also be caused by a faulty Inverter.
If the fuse trips repeatedly - contact service personnel.
Note that this ALARM needs to be acknowledged in the ALARM list
in order to turn off the Alarm Indicator which is visible in the left
hand upper corner on all screens.
Use the ALARM button to go to alarm log menu.
When the thermal relay or fuse for the cylinder motor has tripped, the problem may have been be
caused by too much material inside cylinder which makes the motor unable to cope with the weight
in the cylinder. Check if this is the case by checking filling level inside cylinder. Check if the outlet pipe
is blocked and make sure that material can be discharged freely. If necessary, empty material from the
inspection hatches on the cylinder.
WARNING! NEVER FILL THE CYLINDER WITH COMPOSTING MATERIAL ABOVE THE
RECOMMENDED FILLING LEVEL OF 60-70% SINCE THIS CAN CAUSE SERIOUS DAMAGE TO THE
COMPOSTER!