29
Programming Mode 22
4
Reserved
5
Reserved
6
Reserved
7
Reserved
8
Immediate AC Failure Report
When selected, the control panel will transmit an AC Failure Report immediately upon AC failure. Normally,
there is a 7 hour delay before an AC failure is reported.
Address 005: System Options
Light
1
Reserved
2
Reserved
3
Reserved
4
Reserved
5
Reserved
6
Master User Allowed to Assign Groups to Access Codes
When “on”, a master user may assign groups to Access Codes using Mode 03.
7
Reserved
8
Forced Arming on Delay and Delay/Instant Zones Only
When “on”, the Delay or Delay/Instant zones may be left open while attempting to arm the system. However,
these zones must be closed before the end of the Exit Delay if the Groups to which they are assigned are
armed. If a Delay zone remains open after the Exit Delay expires, the Entry Delay for the affected Groups will
commence and an alarm will sound at the end of the Entry Delay if one of the affected Groups is not disarmed.
If a Delay/Instant zone (Type 6 or E) is left open and all of the Groups to which it is assigned are armed, an
alarm will be generated immediately.
Address 006: System Options
Light
1
Reserved
2
Reserved
3
Reserved
4
Arming By Central Station
When “on”, the central station may arm the system remotely.
5
Disarming By Central Station
When “on”, the central station may disarm the system remotely.
6
Force Auto-Arm and/or Arming by Central Station
When “on”, the system will bypass all opened zones, regardless of the zone type, when an Exit Delay
generated by the Auto-Arming or Arming by Central Station functions begins.
7
Reserved
8
Reserved
Address 007: System Options
Light
1
Reserved
2
Auto Clear Bypass on Entry
When “on”, all zone bypasses will be automatically cleared when the system is disarmed.
3
All Closed Report
When “on”, the system will report a closing only when all Groups are armed. If any of the Groups are not
armed, the closing code will not be sent. If all Groups are armed, the opening code will be sent when one of
the Groups is disarmed. This function will only operate when Open / Close Reporting is selected in Mode 22
Address [001].