![Sur-Gard SG Security DV8OOO Instruction Manual Download Page 25](http://html1.mh-extra.com/html/sur-gard/sg-security-dv8ooo/sg-security-dv8ooo_instruction-manual_1406536025.webp)
21
[229] - [269]
Trouble Definitions
Program a 1-digit Trouble Definition at each address from [229] through [269].
Do not assign type 5, 6, A or E to
the Trouble Definitions. The Trouble Definitions are programmed at the addresses listed here:
Address
Restore Code
[229]
Auxiliary Zone Alarm
[230]
Printer Failure
[231]
Fire Trouble
[232]
AC Failure
[233]
Auxiliary Power Fuse
[234]
Siren Cut
[235]
Low Battery
[236]
Fire Alarm
[237]
DVAC Line Fault
[238]
For Future Use
[239]
EEPROM Failure
[240]
Fail to Arm Schedule 1
[241]
Fail to Arm Schedule 2
[242]
Fail to Arm Schedule 3
[243]
For Future Use
[244]
Ground Fault
[245] - [265]
For Future Use
[266]
Fire Key Alarm
[267]
Panic Key Alarm
[268]
Auxiliary Key Alarm
[269]
Invalid Code
[270] - [300]
For Future Use
[301] - [315]
Alarm and Restoral Codes for Zones 1 to 8
and Trouble Zones 1 to 7
Program a 2-digit Alarm Code at each address from [301] through [315].
[316] - [428]
For Future Use
[429] - [444]
Trouble Alarm and Restoral Reporting Codes
Program a 2-digit Trouble Alarm Reporting Code at each address from [429] through [444]. The reporting codes
for each Trouble Condition are programmed at the addresses as shown below:
Address
Trouble Condition
[429]
Auxiliary Zone Alarm
[430]
Printer Failure
[431]
Fire Trouble
[432]
AC Failure
[433]
Auxiliary Power Fuse
[434]
Siren Cut
[435]
Low Battery
[436]
Fire Alarm
[437]
DVAC Line Fault
[438]
For Future Use
[439]
EEPROM Failure
[440]
Fail to Arm on Schedule 1
[441]
Fail to Arm on Schedule 2
[442]
Fail to Arm on Schedule 3
[443]
For Future Use
[444]
Ground Fault
Programming Mode 20