![Sur-Gard SG Security DV8OOO Instruction Manual Download Page 22](http://html1.mh-extra.com/html/sur-gard/sg-security-dv8ooo/sg-security-dv8ooo_instruction-manual_1406536022.webp)
18
PROGRAMMING MODE 20
RS-232 / 10mA Loop DVACS Option
Either an RS-232 connection or 10mA loop may be used as the interface between the DV8000 and the F1/F2
subset. The interface option is selected by setting the jumpers “LK1”, “LK2”, “LK3”, “LK4” and “LK5” on the
DV8000 Control Panel.
To use the RS-232 option, all jumpers must be set to the “V” position.
To use the 10mA loop option, all jumpers must be set to the “C” position.
Refer to the Hook-Up Diagram in this manual for the location of the jumpers on the DV8000 Control Panel.
It is important that all jumpers be set in the same position. If the jumpers are improperly configured,
damage to the F1/F2 subset or the DV8000 may occur.
[000] - [019]
For Future Use
[020]
Panel Identification Code
Address [020] contains the control panel identification code. Enter a 2-digit number in this Address.
[021]
All Call Select
All Call Options
The “All Call” function allows control panels to transmit alarms to the central station immediately without having to
wait to be polled. An “All Call” command is transmitted from the central station after every eighth control panel is
polled. If a control panel is in alarm when it receives that “All Call” command, it can transmit the alarm if it has
been programmed to respond to the command.
All Call Programming Recommendations
• The control panel should be programmed to respond to one “All Call” command only
• Response to All Call 1 and All Call 2 should be evenly divided amongst all systems polled by the central station
• Two systems connected to the same modem (F1/F2 subset) should each have a different All Call response
selected
• With Automatic All Call Selection, both odd and even identification codes should be programmed
• No Response on All Call should be selected for installations with lower security requirements
• When more than two systems are connected to the same modem, the third and any additional systems should be
programmed for No Response on All Call
In Address [021], enter a 1-digit code from the options below:
0
No Response on All Call
1
Response on All Call 1 Only
2
Response on All Call 2 Only
3
Response on All Call 1 and 2
4
Automatic All Call Selection. Odd identification codes will respond to All Call 1;
even identification codes will respond to All Call 2
Note: Enter a digit from 0 to 4 only. Entering a number greater that 4 will
select Option 4.
[022]
All Call Answer
The security system may transmit both alarms and restorals on the All Call command. However, it is preferable to
program the system to transmit the alarms only, and then to wait to be polled before transmitting the restoral
codes.
Enter 0 or 1 for one of the options shown below:
0
All Call Answer on Alarm and Restoral
1
All Call Answer on Alarm Only
[023] - [100]
For Future Use
firealarmresources.com
firealarmresources.com