Bypassed Zone Display on Exit
When “on”, the Keypad will display all zones that are bypassed when the system is armed.
6
Quick-Exit
When enabled, entering [
∗
][0] when the system is fully armed will allow the user 2 minutes to exit the premises
through any delay zone without altering the status of the system. After [
∗
][0] is entered, only one delay zone may
be activated. Any additional activity on any other armed zone will cause an alarm to be generated.
7
No Arming on AC Failure and Low Battery
When “on”, the system cannot be armed when the battery is low and AC power is not present.
8
Reserved
Address 003: System Options
Light
1
Master Code Not Changeable
When “on”, the user is unable to edit the First Master Code.
2
Only Master Code Able to Send User Messages
When “on”, the Master Code will be required to send messages to the monitoring station. When this option is
“off”, an Arm/Disarm/Bypass Access Code may also be used to send user messages.
3
Immediate Restore
When “on”, restoral codes for all zones are transmitted to the monitoring station immediately after the loop
returns to normal, even if the bell/siren is active. When this option is selected, it is suggested that the All Call
Answer on Alarm and Restore option in Mode 20 Address [022] also be selected.
4
Memory Security Switch
When “on”, the installer must short the pins marked “LK6” together in order to enter the Installer Programming Modes.
5
Keyswitch Arming/Disarming
When “on”, a normally-open momentary-contact keyswitch may be used to arm and disarm the system. The
keyswitch must be wired to the AUXIN and COM terminals. Note that the end-of-line resistor must not be
removed.
6
Maintained Keyswitch Arming/Disarming
When “on”, a normally-open maintained keyswitch may be used to arm and disarm the system. Light 5 Keyswitch
Arming/Disarming must be enabled, and the keyswitch must be connected to the AUXIN and COM terminals.
Note that the end-of-line resistor must not be removed.
Note that the Keyswitch is intended for supplemental use only, and does not replace a keypad.
7
Reserved
8
Reserved
Address 004: System Options
Light
1
Programmable Output 3 Normally High
When “on”, Programmable Output 3 will be normally high. Entering User Mode 04 or 05 will momentarily turn
Programmable Output 3 off. This feature can be used, for example, to reset smoke detectors.
2
Installer Code Programmable / Installer Lockout
When “on”, the Installer Code will not be reset when the system’s programming is restored to the factory default
settings.
When “off”, the Installer Code will be reset to the factory default of [8000] when the system’s programming is
restored to the factory default settings.
WARNING: If the installer code is forgotten and this option is “ON”, it will be impossible to retrieve the installer code.
3
Keypad Lockout
When “on”, the Keypad will refuse to accept any Access Codes after 5 consecutive invalid codes are entered.
The Keypad will remain locked out for 7 minutes. If any code is keyed in during the lockout period, the lockout
timer will be reset and the Keypad will remain locked out for another 7 minutes. Only after the lockout time has
expired may a valid Access Code be entered to disarm the system.