5. Customize Settings
90
Copyright © 2008, Suprema Inc. On the web: www.supremainc.com
-
Time sync with Server
- check this box to synchronize the
device time with the time maintained at the server.
• RS485
-
Mode
- set the mode for a device connected via RS485 (
Disable
,
Host
,
Slave
, or
PC Connection
).
-
Baudrate
- set the baud rate for a device connected via RS485
(
9600
to
115200
).
5.1.2.4 Access Control tab
The Access Control tab allows you to customize entrance limit settings
and default access groups for a BioEntry Plus device.
• Entrance Limit Setting
-
Timed APB (min)
- set the duration (in minutes) that a user will
be unable to regain entry to an area via the device. Once a user
has gained entry, the device will reject the user’s card or finger-
print authorization for the time period specified here.
-
Option 1-4
- click the checkbox to enable an entrance limit
setting, and then specify the effective hours for the entrance limit.
-
Max Number of Entrance
- set the maximum number of entries
allowed during the specified time limit.
•
Default Access Group Setting
- select a default access group to be
applied to new users who have not been assigned to another access
group.