5. Customize Settings
95
Copyright © 2008, Suprema Inc. On the web: www.supremainc.com
5.2.1 Details tab
The Details tab allows you to specify which devices are used on the inside or
outside of a door, how the devices control the door, and anti-passback features.
When connecting two devices to a single door, the devices should be connected
to each other by RS485. In this case, the I/O ports of only one device can be
used. Specify which device’s I/O ports to use in the “IO Device” drop-down list.
•
Inside Device
- select a device to use on the inside of the door.
•
Outside Device
- select a device to use on the outside of the door.
•
Unlock Time
- select a schedule when the door should normally be
unlocked. During this time, door relays are active.
•
Lock Time
- select a schedule when the door should normally be locked.
During this time, door relays are inactive.
•
IO Device
- when using two devices on a single door, specify which device’s
IO ports will be used.
•
Door Relay
- select a door relay.
•
Exit Button
- select a device input to use for an exit button (
Disable
or
Input 0
and
Input 1
for each device added).
•
(Switch Type)
- set the normal position of the input used for an exit button
(
N/O-normally open
or
N/C-normally closed
).
•
Door Status
- set an input for a sensor that detects the current status of
the door.
•
(Switch Type)
- set the normal position of the input used for a door status
sensor (
N/O-normally open
or
N/C-normally closed
).
•
Door Open Period (sec)
- set the duration (in seconds) that a door relay
should be activated when a door is opened. After this duration, the relay will
stop sending the signal to open the door. The default is three seconds.