5. Customize Settings
92
Copyright © 2008, Suprema Inc. On the web: www.supremainc.com
must enter the master password for a BioStation device or provide
authentication locally for a BioEntry Plus device.
•
Schedule
- set the schedule for the input actions (
Always
,
Disable
,
or custom schedule).
•
Duration (ms)
- set the duration (in milliseconds) an input signal
must last to trigger the specified action.
5.1.2.6 Output tab
The Output tab lists output settings you have specified for a BioEntry
Plus device. Buttons at the bottom of the tab allow you to add, modify, or
delete output settings. To add or modify settings, you must specify them
from the Output Setting window. For more information about configur-
ing output settings, see section 3.8.3.1.
•
Device Type
- select the device type for which you will add or modify
settings.
•
Port
- select an output port (
Relay 0
). For Secure I/O devices, these
settings are available:
Relay 0
or
Relay 1
.
•
Alarm On Event
- specify settings and click
Add
to add the event to
the Alarm On Event list. These events will activate an alarm.
-
Event
- select an event that will activate an alarm (
Auth Success
,
Auth Fail
,
Auth Duress
,
Anti-passback Fail
,
Access Not
Granted
,
Entrance Limited
,
Admin Auth Success
,
Tamper On
,
Door Opened
,
Door Close
,
Forced Open Door
,
Held Open Door
,
or
Detect Input #1-3
).