5. Customize Settings
86
Copyright © 2008, Suprema Inc. On the web: www.supremainc.com
image at a time can be used as a logo or notice, while up to 16
images can be displayed (at a set interval) in a slide show.
-
Notice
- click this button to create a notice that will be shown on
the BioStation display. After creating a notice, you can click
Apply
to apply the notice to the current device or
Apply to Others
to
apply the notice to additional devices.
-
Volume
- set the volume of the BioStation device (
10%
to
100%
).
-
Msg Timeout
- set the length of time that a failure or
confirmation message will be displayed.
•
Background Image
- click this checkbox to upload new background
images. Click
Add
to locate and add a new image file.
•
Sound
- click this checkbox to enable and add custom event sounds.
Click an event from the list and then click
Add
to locate and add a
new sound file.
5.1.1.8 Wiegand tab
The Wiegand tab allows you to configure the Wiegand format for a
BioStation device. Click
Change Format
to launch the Wiegand
Configuration wizard. For more information on configuring the Wiegand
format, see section 3.2.5.
•
Wiegand Input
- assign the Wiegand input:
-
Disabled
- the input will not be used.
-
Wiegand [Card]
- the ID field of the Wiegand string is interpreted
as a card ID.
-
Wiegand [User]
- the ID field of the Wiegand string is interpreted
as a user ID.
•
Wiegand Output
- assign the Wiegand output:
-
Disabled
- the output will not be used.
-
Wiegand [Card]
- inserts the card ID of the authenticated user in
the ID field of the Wiegand string.