Chapter 6: Advanced Chassis Setup
6-3
6-3 System
Fans
Four 4-cm heavy duty counter-rotating fans provide the cooling for the SuperServer
6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF. Each fan unit is actually made up
of two fans joined back-to-back, which rotate in opposite directions. This counter-
rotating action generates exceptional air
fl
ow and works to dampen vibration levels.
It is very important that the chassis top cover is properly installed and making a
good seal in order for the cooling air to circulate properly through the chassis and
cool the components. See Figure 6-2.
System Fan Failure
Fan speed is controlled by system temperature via a BIOS setting. If a fan fails,
the remaining fan will ramp up to full speed and the overheat/fan fail LED on the
control panel will turn on. Replace any failed fan at your earliest convenience with
the same type and model (the system can continue to run with a failed fan).
Remove the top chassis cover while the system is still running to determine which
of the two fans has failed. Then power down the system before replacing a fan.
Removing the power cords is also recommended as a safety precaution.
Replacing System Fans
1. After determining which fan has failed, turn off the power to the system.
2. Unplug the fan cable from the serverboard and remove the failed fan from the
chassis.
3. Replace the failed fan with an identical 4-cm, 12 volt fan (available from
Supermicro: p/n FAN-0086L4).
4. Push the new fan into the vacant space in the housing while making sure the
arrows on the top of the fan (indicating air direction) point in the same direc-
tion as the arrows on the other fans.
5. Reposition the fan housing back over the two mounting posts in the chassis,
then reconnect the fan wires to the same chassis fan headers you removed
them from.
6. Power up the system and check that the fan is working properly and that
the LED on the control panel has turned off. Finish by replacing the chassis
cover.
Summary of Contents for SUPERSERVER 6016T-NTF
Page 5: ...v Preface Notes...
Page 48: ...4 20 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...
Page 76: ...5 28 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...
Page 87: ...Chapter 6 Advanced Chassis Setup 6 11 Figure 6 6 Removing Replacing the Power Supply...
Page 88: ...6 12 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...
Page 114: ...A 2 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...