7-16
S
UPER
S
ERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual
User intervention: No action is required. However, consider checking the CPU fans
and the chassis ventilation for blockage.
High
– The processor is running hot. This is a ‘caution’ level since the CPU’s ‘Tem-
perature Tolerance’ has been reached (or has been exceeded) and may activate
an overheat alarm.
User intervention: If the system buzzer and Overheat LED has activated, take action
immediately by checking the system fans, chassis ventilation and room temperature
to correct any problems.
Notes
: 1. The system may shut down if it continues for a long period to
prevent damage to the CPU.
2. The information provided above is for your reference only. For more
information on thermal management, please refer to Intel’s Web site at
www.Intel.com.
System Temperature:
The system temperature will be displayed (in degrees in
Celsius and Fahrenheit) as it is detected by the BIOS.
Fan 1 ~ Fan 8 Reading
This feature displays the fan speed readings from fan interfaces Fan 1 through
Fan 8.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When the
CPU on-die temperature increases, the fan speed will also increase, and vice versa.
Select Workstation if your system is used as a Workstation. Select Server if your
system is used as a Server. Select “Disabled, (Full Speed @12V)” to disable the fan
speed control function and allow the onboard fans to constantly run at the full speed
(12V). The Options are:
Disabled (Full Speed)
, 4-pin (Server), 4-pin (Workstation),
4-pin (Quiet) and 4-pin (Super Quiet).
Voltage Monitoring
CPU1 Vcore, CPU2 Vcore, 1.5V, 5V, 5VSB, 12V, -12V, 3.3Vcc, 3.3VSB, VBAT
and Vtt.
ACPI Confi guration
Use this feature to con
fi
gure Advanced Con
fi
guration and Power Interface (ACPI)
power management settings for your system.
Summary of Contents for SUPERSERVER 6016T-NTF
Page 5: ...v Preface Notes...
Page 48: ...4 20 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...
Page 76: ...5 28 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...
Page 87: ...Chapter 6 Advanced Chassis Setup 6 11 Figure 6 6 Removing Replacing the Power Supply...
Page 88: ...6 12 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...
Page 114: ...A 2 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...