Chapter 5: Advanced Serverboard Setup
5-1
Chapter 5
Advanced Serverboard Setup
This chapter covers the steps required to install processors and heatsinks to the
X8DTU-F serverboard, connect the data and power cables and install add-on
cards. All serverboard jumpers and connections are described and a layout and
quick reference chart are included in this chapter. Remember to close the chas-
sis completely when you have
fi
nished working on the serverboard to protect and
cool the system suf
fi
ciently.
5-1 Handling the Serverboard
Static electrical discharge can damage electronic com ponents. To prevent damage
to printed circuit boards, it is important to handle them very carefully (see Chapter 4).
Also note that the size and weight of the serverboard can cause it to bend if handled
improperly, which may result in damage. To prevent the serverboard from bending,
keep one hand under the center of the board to support it when handling.
The following measures are generally suf
fi
cient to protect your equipment from
static discharge.
Precautions
•
Use a grounded wrist strap designed to prevent static discharge.
•
Touch a grounded metal object before removing any board from its antistatic
bag.
•
Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or gold contacts.
•
When handling chips or modules, avoid touching their pins.
•
Put the serverboard, add-on cards and peripherals back into their antistatic
bags when not in use.
Unpacking
The serverboard is shipped in antistatic packaging to avoid static damage. When
unpacking the board, make sure the person handling it is static protected.
Summary of Contents for SUPERSERVER 6016T-NTF
Page 5: ...v Preface Notes...
Page 48: ...4 20 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...
Page 76: ...5 28 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...
Page 87: ...Chapter 6 Advanced Chassis Setup 6 11 Figure 6 6 Removing Replacing the Power Supply...
Page 88: ...6 12 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...
Page 114: ...A 2 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...