51
Chapter 3: Maintenance and Component Installation
System Cooling
The chassis contains eight mid-chassis fans and two air shrouds to direct air flow. It also
allows adding up to three optional exhaust fans (MCP-240-84807-0N).
Mid-Chassis Fans
The chassis contains eight 9-cm high-performance fans. Fan speed is controlled by IPMI
depending on the system temperature. If a fan fails, the remaining fans will ramp up to full
speed. The system will continue to run with a failed fan, although it may shut down if the
heat gets too great. Replace any failed fan at your earliest convenience with the same model.
Failed fans can be identified through the IPMI.
Changing a Mid-Chassis Fan
1. Determine which fan has failed using IPMI, or if necessary, open the chassis while the
system is running. Never run the server for long without the chassis cover.
2. Push the release tab and pull the failed fan from the chassis. Fans can be replaced
while the system is running.
3. Replace the failed fan with an identical fan, available from Supermicro. Push the new
fan into the housing, making sure the air flow direction is the same.
4. Check that the fan is working properly and that the LED on the control panel has turned
off. Finish by replacing the chassis cover.
Figure 3-9. Replacing a Front System Fan
Release Tab
Summary of Contents for SuperServer 8049U-E1CR4T
Page 1: ...USER S MANUAL Revision 1 0a SuperServer 8049U E1CR4T...
Page 54: ...SuperServer 8049U E1CR4T User s Manual 54 Figure 3 13 Installing the PWS Air Shroud...
Page 157: ...Appendix G BSMI Chinese Safety Warnings 157 WARNINGS 1 100V 240V 10 2 3 4 1 2 3 4 5 1 2 3 4...
Page 158: ...158 1 2 1 2 3 4 SuperServer 8049U E1CR4T User s Manual...
Page 160: ...160 SuperServer 8049U E1CR4T User s Manual 100 127V 60 50Hz 12 0A 200 240V 60 50Hz 9 6A...