Chapter 3: Maintenance and Component Installation
DCPMM Population Table based on the 82xx/62xx/52xx
Use the following tables to choose recommended slots with which to populate DCPMMs and
DIMMs.
Symmetric Population for 2-2-2 Channel Configuration
(for each processor)
Modes
DIMMF1
DIMMF2
DIMME1
DIMME2
DIMMD1
DIMMD2
DIMMA2
DIMMA1
DIMMB2
DIMMB1
DIMMC2
DIMMC1
AD
DRAM1
DCPMM DRAM1
DCPMM DRAM1
DCPMM DCPMM DRAM1
DCPMM DRAM1
DCPMM DRAM1
MM
DRAM1
DCPMM DRAM1
DCPMM DRAM1
DCPMM DCPMM DRAM1
DCPMM DRAM1
DCPMM DRAM1
AD +
MM
DRAM3
DCPMM DRAM3
DCPMM DRAM3
DCPMM DCPMM DRAM3
DCPMM DRAM3
DCPMM DRAM3
AD: App Direct, MM: Memory Mode
Symmetric Population for 2-1-1 Channel Configuration
(for each processor)
Modes
DIMMF1
DIMMF2
DIMME1
DIMME2
DIMMD1
DIMMD2
DIMMA2
DIMMA1
DIMMB2
DIMMB1
DIMMC2
DIMMC1
AD
DRAM1
DRAM1
DRAM1
DCPMM DCPMM DRAM1
DRAM1
DRAM1
MM
DRAM2
DRAM2
DRAM2
DCPMM DCPMM DRAM2
DRAM2
DRAM2
AD +
MM
DRAM3
DRAM3
DRAM3
DCPMM DCPMM DRAM3
DRAM3
DRAM3
Symmetric Population for 2-2-1 Channel Configuration
(for each processor)
Modes
DIMMF1
DIMMF2
DIMME1
DIMME2
DIMMD1
DIMMD2
DIMMA2
DIMMA1
DIMMB2
DIMMB1
DIMMC2
DIMMC1
AD
DRAM1
DRAM1
DCPMM DRAM1
DCPMM DCPMM DRAM1
DCPMM DRAM1
DRAM1
MM
DRAM1
DRAM1
DCPMM DRAM1
DCPMM DCPMM DRAM1
DCPMM DRAM1
DRAM1
AD +
MM
DRAM3
DRAM3
DCPMM DRAM3
DCPMM DCPMM DRAM3
DCPMM DRAM3
DRAM3
Symmetric Population for 1-1-1 Channel Configuration
(for each processor)
Modes
DIMMF1
DIMMF2
DIMME1
DIMME2
DIMMD1
DIMMD2
DIMMA2
DIMMA1
DIMMB2
DIMMB1
DIMMC2
DIMMC1
AD
DCPMM
DRAM1
DRAM1
DRAM1
DRAM1
DCPMM
MM
DCPMM
DRAM1
DRAM1
DRAM1
DRAM1
DCPMM
AD +
MM
DCPMM
DRAM3
DRAM3
DRAM3
DRAM3
DCPMM
Asymmetric Population for 2/1-1-1 Channel Configuration
(for each processor)
Modes
DIMMF1
DIMMF2
DIMME1
DIMME2
DIMMD1
DIMMD2
DIMMA2
DIMMA1
DIMMB2
DIMMB1
DIMMC2
DIMMC1
AD
DRAM1
DRAM1
DRAM1
DCPMM DRAM1
DRAM1
DRAM1
Legend (for the five tables above)
DDR4 Type
Capacity
DIMM1
RDIMM 3DS RDIMM LRDIMM 3DS LRDIMM Any Capacity
DIMM2
RDIMM -
-
-
Refer to the Validation Matrix
below.
DIMM3
RDIMM 3DS RDIMM LRDIMM -
Note
: DDR4 single rank x8 is not available for DCP Memory Mode or App-Direct Mode.
Summary of Contents for SuperServer 8049U-E1CR4T
Page 1: ...USER S MANUAL Revision 1 0a SuperServer 8049U E1CR4T...
Page 54: ...SuperServer 8049U E1CR4T User s Manual 54 Figure 3 13 Installing the PWS Air Shroud...
Page 157: ...Appendix G BSMI Chinese Safety Warnings 157 WARNINGS 1 100V 240V 10 2 3 4 1 2 3 4 5 1 2 3 4...
Page 158: ...158 1 2 1 2 3 4 SuperServer 8049U E1CR4T User s Manual...
Page 160: ...160 SuperServer 8049U E1CR4T User s Manual 100 127V 60 50Hz 12 0A 200 240V 60 50Hz 9 6A...