1-4
1-5
Chapter 1: Introduction
S
UPER
S
TORAGE
S
YSTEM 6037R-E1R16N User's Manual
Figure 1-1. Intel C600 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
Figure 1-2. X9DRi-LN4F+ Serverboard
PROCESSOR
PROCESSOR
QPI
#1
DDR3 DIMM
#2
DDR3 DIMM
DDR3 DIMM
#3
DDR3 DIMM
DDR3 DIMM
#3
#2
#1
DDR3 DIMM
G
A
SSB
Intel C606/C602
PEG0
DMI
PEG1 [4:1]
USB
LPC
LAN
RJ45
RJ45
#1
SATA
SYSTEM
BIOS
CPU REAR
CPU FRONT
PEG1_8
PCI-E x16 Slot
USB
REAR
HDR 2X5
0,1
TPM HDR
TYPE-A
REAR
2,3
QPI
DDR3 DIMM
B
DDR3 DIMM
D
C
H
F
E
Socket 1
Socket 2
#1
#2
#3
#1
#2
#3
#1
#2
#3
#1
#2
#3
#1
#2
#3
#1
#2
#3
P0
P0
P1
P1
PE3
PE2
PE1 DMI
DMI
#2
PCI-E x8 Slot
PCI-E x16 Slot
#3
x4
x16
x16
x4
HDR 2X5
BMC VGA
VGA CONN
DDR III
PHY1
LAN
RTL8211
SPI
x1
RJ45
RJ45
#6
PCI-E x16 Slot
#5
PCI-E x16 Slot
#4
PCI-E x16 Slot
x16
x4
x4 [7.4]
[3.0]
SIO
W83527
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
4,5
6, 7
PE3 PE2
PE1
9
SATA
SCU
#1~#6
#1~#8
(For X9DR3
-LN4F+ Only)
(4 SATA2 for X9DRi
-LN4F+ Only)
JRK1
JF1
JPI2C1
JPW3
JPW2
JPW1
JSD1
SP1
J18
J17
JBAT1
JP6
JP7
JI2C2 JI2C1
JL1
JOH1
FANB
FANA
FAN4
FAN3
FAN2
FAN6
FAN1
SW1
JPP1
JPP0
J21
JBT1
LEM1
JWP1
JPG1
JWD1
JPL1
JPME2
JPME1
USB4/5
JTPM1
XDP-PCH
(in X8 Slot)
CPU2 Slot6 PCI-E 3.0x8
CPU2 Slot5 PCI-E 3.0 x16
CPU2 Slot4 PCI-E 3.0 x16
CPU1 Slot3 PCI-E 3.0 x16
CPU1 Slot2 PCI-E 3.0 x4
BIOS BOX
CPU1 Slot1 PCI-E 3.0 x16
SAS0~3
SAS4~7
I-SATA0
I-SATA1
P2 DIMMF3
P2 DIMMF1
P2 DIMMF2
P2 DIMME3
P2 DIMME2
P2 DIMME1
P2 DIMMG1
P2 DIMMH1
P2 DIMMG3
P2 DIMMG2
P2 DIMMH2
P2 DIMMH3
COM1
USB6/7
UID
IPMI_LAN
Alaways populate DIMMx1 first
P1 DIMMA2
P1 DIMMA1
P1 DIMMB3
P1 DIMMB2
P1 DIMMB1
P1 DIMMA3
P1 DIMMC1
P1 DIMMC2
P1 DIMMC3
P1 DIMMD1
P1 DIMMD2
P1 DIMMD3
CPU2
I-SATA5
I-SATA4
I-SATA3
I-SATA2
LAN2/4
VGA
XDP-CPU
CPU1
COM2
BMC
CTRL
LAN1/3
USB 0/1
KB/Mouse
JBR1
PHY
FAN5
BIOS
LAN
CTRL
PCH
LE1
X9DR6-LN4F+/X9DRi-LN4F+
Rev. 1.10
Alaways populate DIMMx1 first
USB9
SAS
CTRL
USB 2/3
JSTBY1
IPMB
1
1
JD1
JF2
LE2
JPB1
JBMC1
JBOD ExpansionPort/Cable
AOC-SAS2LP-H8iR
N
ote:
The SSG-6037R-E1R16N comes pre-installed with a Hardware RAID con-
troller installed in PCI-E slot 1 and a JBOD expansion port installed in PCI-E slot
2. Serverboard SAS components shown in the figure above are not included on
the X9DRi-LN4F+
Summary of Contents for Supero 6037R-E1R16N
Page 1: ... SUPER STORAGE SYSTEM 6037R E1R16N SUPER USER S MANUAL 1 0c ...
Page 14: ...2 8 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Page 17: ...3 4 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Page 28: ...4 20 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Page 46: ...5 34 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Page 53: ...6 12 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Page 70: ...7 32 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Page 72: ...A 2 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...