Chapter 5: Advanced Serverboard Setup
5-19
5-18
S
UPER
S
TORAGE
S
YSTEM 6037R-E1R16N User's Manual
Reset Button
The Reset Button connection is
located on pins 3 and 4 of JF1 and
attaches to the reset switch on the
computer chassis. See the table on
the right for pin definitions.
Power Button
The Power On connection is on pins
1 and 2 of JF1. These should be
connected to the chassis power but-
ton. See the table on the right for pin
definitions.
5-8 Connector Definitions
Required Connection
ATX Power 24-pin Connector
Pin Definitions
Pin# Definition Pin # Definition
13
+3.3V
1
+3.3V
14
-12V
2
+3.3V
15
COM
3
COM
16
PS_ON
4
+5V
17
COM
5
COM
18
COM
6
+5V
19
COM
7
COM
20
Res (NC)
8
PWR_OK
21
+5V
9
5VSB
22
+5V
10
+12V
23
+5V
11
+12V
24
COM
12
+3.3V
Reset Button
Pin Definitions (JF1)
Pin# Definition
3
Reset
4
Ground
Power Button
Pin Definitions (JF1)
Pin# Definition
1
Power Signal
2
Ground
Secondary Power Connector
JPW2 and JPW3 must also be con-
nected to the power supply. See the
table on the right for pin definitions.
+12V 8-pin Power
Pin Definitions
Pins Definition
1 - 4
Ground
5 - 8
+12V
Warning
: To provide adequate power
supply to the serverboard, be sure to
connect JPW1 and both JPW2 and
JPW3 to the power supply. Failure
to do so will void the manufacturer
warranty on your power supply and
serverboard.
Power Connectors
A 24-pin main power supply connec-
tor (JPW1) and two 8-pin CPU power
connectors (JPW2/3) must be con-
nected to the power supply. These
power connectors meet the SSI EPS
12V specification. See the table on the
right for pin definitions.
Overheat/Fan Fail LED (OH)
Connect an LED to the OH connection
on pins 7 and 8 of JF1 to provide ad-
vanced warning of chassis overheat-
ing. Refer to the table on the right for
pin definitions.
HDD LED
The HDD LED connection is located
on pins 13 and 14 of JF1. This LED
is used to display all hard drive activ-
ity. See the table on the right for pin
definitions.
OH/Fan Fail LED
Pin Definitions (JF1)
Pin# Definition
7
Vcc
8
Ground
NIC2 LED
Pin Definitions (JF1)
Pin# Definition
9
Vcc
10
Ground
HDD LED
Pin Definitions (JF1)
Pin# Definition
13
Vcc
14
HD Active
NIC2 (JLAN2) LED
The LED connections for JLAN2 are
on pins 9 and 10 of JF1. Attach an
LED cable to display network activ-
ity. See the table on the right for pin
definitions.
NIC1 LED
Pin Definitions (JF1)
Pin# Definition
11
Vcc
12
Ground
NIC1 (JLAN1) LED
The LED connections for JLAN1 are
on pins 11 and 12 of JF1. Attach an
LED cable to display network activ-
ity. See the table on the right for pin
definitions.
OH/Fan Fail Indicator
Status
State Definition
Off
Normal
On
Overheat
Flash-
ing
Fan Fail
Power Fail LED
The Power Fail LED connection is
located on pins 5 and 6 of JF1. Re-
fer to the table on the right for pin
definitions.
PWR Fail LED
Pin Definitions (JF1)
Pin# Definition
5
Vcc
6
Ground
Summary of Contents for Supero 6037R-E1R16N
Page 1: ... SUPER STORAGE SYSTEM 6037R E1R16N SUPER USER S MANUAL 1 0c ...
Page 14: ...2 8 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Page 17: ...3 4 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Page 28: ...4 20 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Page 46: ...5 34 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Page 53: ...6 12 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Page 70: ...7 32 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Page 72: ...A 2 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...