background image

Chapter 7: BIOS

7-5

7-4

S

UPER

S

TORAGE

S

YSTEM 6037R-E1R16N User's Manual

AddOn ROM Display Mode

Use this item to set the display mode for the Option ROM. Select Keep Current to 
use the current AddOn ROM Display setting. Select Force BIOS to use the Option 
ROM display mode set by the system BIOS. The options are 

Force BIOS 

and 

Keep Current. 

Bootup Num-Lock

Use this feature to set the Power-on state for the Numlock key. The options are 
Off and 

On

.

Wait For 'F1' If Error

Select Enabled to force the system to wait until the 'F1' key is pressed if an error 
occurs. The options are Disabled and 

Enabled

.

Interrupt 19 Capture

Interrupt 19 is the software interrupt that handles the boot disk function. When this 
item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19 
at bootup and allow the drives that are attached to these host adaptors to function 
as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adap-
tors will not capture Interrupt 19, and the drives attached to these adaptors will not 
function as bootable devices. The options are 

Enabled

 and Disabled. 

Power Configuration

Watch Dog Function

If enabled, the Watch Dog timer will allow the system to reboot when it is inactive 
for more than 5 minutes. The options are Enabled and 

Disabled.

Power Button Function

If this feature is set to Instant_Off, the system will power off immediately as soon 
as the user presses the power button. If this feature is set to 4_Second_Override, 
the system will power off when the user presses the power button for 4 seconds or 
longer. The options are 

Instant_Off

 and 4_Second_Override.

Restore on AC Power Loss

Use this feature to set the power state after a power outage. Select Power-Off for 
the system power to remain off after a power loss. Select Power-On  for the system 
power to be turned on after a power loss. Select Last State to allow the system to 
resume its last state before a power loss. The options are Power-On, Power-Off

 

and 

Last State

.

CPU Configuration

This submenu displays the information of the CPU as detected by the BIOS. It also 

allows the user to configuration CPU settings.

Socket 0 CPU Information

This submenu displays the following information regarding the CPU installed 
in Socket 0.

• 

Type of CPU

• 

CPU Signature

• 

Microcode Patch

• 

CPU Stepping

• 

Maximum CPU Speed

• 

Minimum CPU Speed

• 

Processor Cores

• 

Intel HT (Hyper-Threading) Technology

• 

Intel VT-x Technology

• 

Intel SMX Technology

• 

L1 Data Cache

• 

L1 Code Cache

• 

L2 Cache

• 

L3 Cache

Socket 1

 

This item displays if a CPU is installed in Socket 1.

CPU Speed

 

This item displays the speed of the CPU installed in Socket 0.

64-bit

 

This item indicates if the CPU installed in Socket 0 supports 64-bit technology.

Summary of Contents for Supero 6037R-E1R16N

Page 1: ... SUPER STORAGE SYSTEM 6037R E1R16N SUPER USER S MANUAL 1 0c ...

Page 2: ...id license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPL...

Page 3: ...g uring the serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC836E16 R920B chassis You should follow the procedures given in this chapter when installing removing or reconfiguring SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction to BIOS and provides detail...

Page 4: ...Power 3 3 3 4 Drive Carrier LEDs 3 3 Chapter 4 Standardized Warning Statements for AC Systems 4 1 About Standardized Warning Statements 4 1 Warning Definition 4 1 Installation Instructions 4 4 Circuit Breaker 4 5 Power Disconnection Warning 4 6 Equipment Installation 4 8 Restricted Area 4 9 Battery Handling 4 10 Redundant Power Supplies 4 12 Backplane Voltage 4 13 Comply with Local and National El...

Page 5: ... Rear Exhaust Fans 6 3 6 4 Drive Bay Installation Removal 6 4 Accessing the Drive Bays 6 4 SATA Drive Installation 6 5 Hard Drive Backplane 6 6 Removing the Air Shroud 6 7 DVD ROM Installation 6 8 6 5 Power Supply 6 9 Power Supply Failure 6 9 6 6 Attaching a JBOD Expansion Chassis 6 10 Chapter 7 BIOS 7 1 Introduction 7 1 7 2 Main Setup 7 2 7 3 Advanced Setup Configurations 7 3 7 4 Event Logs 7 23 ...

Page 6: ...r use with the system www supermicro com In addition to the serverboard and chassis various hardware components have been included with the 6037R E1R16N as listed below Two passive CPU heatsinks SNK P0048P Three 8 cm system fans FAN 0126L4 One air shroud MCP 310 29001 0N SATA Accessories One SATA backplane BPN SAS2 836EL1 Twelve drive carriers MCP 220 00075 OB Hardware RAID Controller AOC SAS2LP H...

Page 7: ...2 PCI E 3 0 x4 Rear I O Ports The color coded I O ports include one COM port a VGA port four USB 2 0 ports additional USB headers are included on the serverboard four gigabit Ethernet ports and one external MiniSAS JBOD expansion port A dedicated IPMI LAN port is also included 1 3 Server Chassis Features The following is a general outline of the main features of the SC836E16 R920B server chassis S...

Page 8: ...8 J17 JBAT1 JP6 JP7 JI2C2 JI2C1 JL1 JOH1 FANB FANA FAN4 FAN3 FAN2 FAN6 FAN1 SW1 JPP1 JPP0 J21 JBT1 LEM1 JWP1 JPG1 JWD1 JPL1 JPME2 JPME1 USB4 5 JTPM1 XDP PCH in X8 Slot CPU2 Slot6 PCI E 3 0x8 CPU2 Slot5 PCI E 3 0 x16 CPU2 Slot4 PCI E 3 0 x16 CPU1 Slot3 PCI E 3 0 x16 CPU1 Slot2 PCI E 3 0 x4 BIOS BOX CPU1 Slot1 PCI E 3 0 x16 SAS0 3 SAS4 7 I SATA0 I SATA1 P2 DIMMF3 P2 DIMMF1 P2 DIMMF2 P2 DIMME3 P2 DIM...

Page 9: ...ro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Web Site www supermicro nl Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 235 Taiw...

Page 10: ...rServer 6037R E1R16N It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Read the Rack and Server Precautions in the next section 2 3 Preparing for Setup The box the SuperServer 6037R E1R16N was shipped in should include two sets of rail ass...

Page 11: ...mbient operating tempera ture of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient tempera ture Tmra Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromi...

Page 12: ...information on installing the SuperServer 6037R E1R16N into a rack unit If the 6037R E1R16N has already been mounted into a rack you can skip ahead to Sections 2 5 and 2 6 There are a variety of rack units on the market which may mean the assembly procedure will differ slightly The following is a guideline for installing the 6037R E1R16N into a rack with the rack rails pro vided You should also re...

Page 13: ... chassis into the rack as shown in Figure 2 4 The chassis may not slide into the rack smoothly or easily when installed the first time Some adjustment to the slide assemblies might be needed for easier installation When the server has been pushed completely into the rack you should hear the locking tabs click You ll need to release the safety taps on both sides of the chas sis in order to complete...

Page 14: ...2 8 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...

Page 15: ...sis are in order from left to right a reset button and a power on off button Reset Use the reset button to reboot the system Power This is the main power button which is used to apply or turn off the main system power Turning off system power with this button removes the main power but keeps standby power supplied to the system 3 3 Control Panel LEDs The control panel located on the front of the c...

Page 16: ...installed properly see Chapter 5 This LED will remain flashing or on as long as the indicated condition exists NIC1 Indicates network activity on the JLAN1 port when flashing NIC2 Indicates network activity on the JLAN2 port when flashing HDD Indicates IDE channel activity On the SuperServer 6037R E1R16N this LED indi cates hard and or DVD ROM drive activity when flashing Power Indicates power is ...

Page 17: ...3 4 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...

Page 18: ... configuring components in the Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preve...

Page 19: ...dures couramment utilisées pour éviter les accidents Pour prendre connaissance des traductions des avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil référez vous au numéro de l instruction situé à la fin de chaque avertissement CONSERVEZ CES INFORMATIONS 안전을 위한 주의사항 경고 이 경고 기호는 위험이 있음을 알려 줍니다 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다 모든 장비에 대한 작업을 수행하기 전에 전기회로와...

Page 20: ...systeem op de voedingsbron aansluit サーキッ ト ブレーカー この製品は 短絡 過電流 保護装置がある建物での設置を前提としています 保護装置の定格が250 V 20 Aを超えないこ とを確認下さい Warnung Dieses Produkt ist darauf angewiesen dass im Gebäude ein Kurzschluss bzw Überstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A beträgt Advertencia Este equipo utiliza el sistema de protección contra cortocircuit...

Page 21: ...oleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V 20A Advertencia El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le système doit être débranché de toutes les sources de puissance ains...

Page 22: ...ntés אזהרה רש בלבד מוסמך צוות את להחליף להתקין אי הציוד עבור שירות לתת או הציוד والمدربيه و لتزكيب استبدال أو خدمة الجهاس هذا يسمح أن يجب فقط المؤهليه للمىظفيه 경고 훈련을 받고 공인된 기술자만이 이 장비의 설치 교체 또는 서비스를 수행할 수 있습니다 Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd vervangen of hersteld door geschoold en gekwalificeerd personeel Warnung Diese Einheit ist zur Installation in Bereichen mit bes...

Page 23: ...ٍ ف نتركُبها مناطق محظورة تم انىص َمكن ً إن ىل منطقت محظورة فقط استخذاو خالل من خاصت أداة أو ٌ أ نال أخري وسُهت مألما ومفتاح قفم 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van spe...

Page 24: ...uando el sistema está en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Redundant Po...

Page 25: ...יים החשמל לחוקי תואמת להיות חייבת הציוד المعدات تركيب الكهربائية لل يمتثل أن يجب قىاويه والىطىية المحلية المتعلقة بالكهرباء 경고 시스템이 동작 중일 때 후면판 Backplane 에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud האחורי בפנל מתח אז הרה במהלך להיזהר יש המערכת ...

Page 26: ...vertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilateur du châssis Prenez garde à ce que doigts tournevis et autres objets soient éloigné...

Page 27: ...s que tienen UL o CSA se muestra en el código de otros dispositivos eléctricos que los productos designados por Supermicro solamente 電源コードとACアダプター 製品を設置する場合 提供または指定された接続ケーブル 電源コードとACアダプター を使用下さい 他のケーブルやアダプタを使用すると故障や火災の原因になるこ とがあ り ます 電気用品安全法は ULまたはCSA認定のケーブル UL CSEマークがコードに表 記 を Supermicroが指定する製品以外に使用するこ とを禁止しています ומתא חשמליים מ י AC אזהרה ומתאמים ספקים בכבלים להשתמש יש המוצר את מתקינים כאשר AC אשר...

Page 28: ...4 20 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...

Page 29: ...nt to handle them very carefully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wrist strap designed to prevent Electrostatic Discharge ESD Touch a grounded metal object before remov...

Page 30: ...ly connector JPW1 for con nection to the ATX power supply In addition there are two 8 pin 12V processor power connectors JPW2 and JPW3 that must be connected to your power supply See Section 5 9 for power connector pin definitions Connecting the Control Panel JF1 contains header pins for various front control panel connectors See Figure 5 1 for the pin locations of the various front control panel ...

Page 31: ...hen receiving a serverboard without a processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins are bent otherwise contact your retailer immediately Refer to the Supermicro web site for updates on CPU support OPEN1st WARNING OPEN1st WARNING Press down on the lever labeled Close 1st Pull lever away from the socket Gently push down to pop the load plat...

Page 32: ... labeled Open 1st Use your thumb to gently push the load levers down until the lever locks OPEN1st OPEN1st Lever Lock Push down and lock the lever labeled Open 1st Push down and lock the level labeled Close 1st Gently close the load plate OPEN1st Serverboard Screw 1 Screw 2 Installing a Passive CPU Heatsink 1 Do not apply any thermal grease to the heatsink or the CPU die the required amount has al...

Page 33: ...333 1066 800 SDRAM For best performance install pairs of memory modules of the same type and speed Please refer to our website for any updates to supported memory All channels will run at the fastest common frequency DIMM Installation Installing Memory Modules 1 Insert the desired number of DIMMs into the memory slots starting with P1 DIMMA1 See the Memory Installation Tables on the following page...

Page 34: ...GB 4GB 8GB NA 1066 1333 1600 1866 NA 1066 1333 1600 N A 1066 1333 1600 1866 N A 1066 1333 1600 SRx16 Non ECC 512MB 1GB 2GB NA 1066 1333 1600 1866 NA 1066 1333 1600 N A 1066 1333 1600 1866 N A 1066 1333 1600 SRx8 ECC 1GB 2GB 4GB 1066 1333 1066 1333 1600 1866 1066 1333 1066 1333 1600 1066 1333 1066 1333 1600 1866 1066 1333 1066 1333 1600 DRx8 ECC 2GB 4GB 8GB 1066 1333 1066 1333 1600 1866 1066 1333 1...

Page 35: ...800 1066 800 800 800 1066 800 800 N A N A QRx8 4GB 8GB 16 GB 800 1066 800 800 800 1066 800 800 N A N A Note For detailed information on memory support and updates please refer to the SMC Recommended Memory List posted on our website at http www supermicro com support resources mem cfm Populating LRDIMM ECC Memory Modules Intel E5 2600 v2 Series Processor LRDIMM Memory Support Ranks Per DIMM Data W...

Page 36: ...t included on the X9DRi LN4F Please note that the PCI slots are enabled with the processors CPU2 Slot 4 indicates that the second CPU must be installed to the CPU2 socket to enable this PCI slot JRK1 JF1 JPI2C1 JPW3 JPW2 JPW1 JSD1 SP1 J18 J17 JBAT1 JP6 JP7 JI2C2 JI2C1 JL1 JOH1 FANB FANA FAN4 FAN3 FAN2 FAN6 FAN1 SW1 JPP1 JPP0 J21 JBT1 LEM1 JWP1 JPG1 JWD1 JPL1 JPME2 JPME1 USB4 5 JTPM1 XDP PCH in X8 ...

Page 37: ...tel SB SATA Connectors 0 5 J17 J18 Serial Link General_Purpose IO Headers T SGPIO 1 2 JBAT1 Onboard Battery See Chpt 4 for Used Battery Disposal JD1 Speaker Power LED Indicator JF1 Front Panel Control Header JPI2 C1 System Management SMBbus I2 C Header JITP0 XDP CPU JL1 Chassis Intrusion JOH1 Overheat Fan Fail LED JPI2 C1 Power Supply SMBbus I2 C Header JPW1 ATX 24 Pin Power Connector JPW2 JPW3 12...

Page 38: ...d Power Connectors A 24 pin main power supply connec tor JPW1 and two 8 pin CPU power connectors JPW2 3 must be con nected to the power supply These power connectors meet the SSI EPS 12V specification See the table on the right for pin definitions Overheat Fan Fail LED OH Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad vanced warning of chassis overheat ing Refer to the ta...

Page 39: ...initions JF1 Pin Definition 15 5V Stby 16 Control Chassis Intrusion The Chassis Intrusion header is des ignated JL1 Attach an appropriate cable from the chassis to inform you of a chassis intrusion when the chas sis is opened Chassis Intrusion Pin Definitions Pin Definition 1 Intrusion Input 2 Ground Ethernet Ports Four Ethernet ports are located on the I O backplane A dedicated IPMI LAN port is a...

Page 40: ...n Definition 1 Vcc 2 Data 3 Data 4 Ground 5 NA Overheat LED Fan Fail JOH1 The JOH1 header is used to connect an LED to provide warning of chassis overheating or fan failure This LED will blink to indicate a fan failure Refer to the tables on right for LED status and pin definitions Overheat LED Pin Definitions Pin Definition 1 5vDC 2 OH Active OH Fan Fail LED States State Message Solid Overheat Bl...

Page 41: ... 2 Ground 3 Button In 4 Ground UID LED LE2 Status Color State OS Status Blue On Windows OS Unit Identified Blue Blinking Linux OS Unit Identified Note UID can also be triggered via IPMI For more information on IPMI please refer to the IPMI User s Guide posted on our Website http www supermicro com 5 9 Jumper Settings Explanation of Jumpers To modify the operation of the serverboard jumpers can be ...

Page 42: ... Setting Definition Open Write_Protect Disabled Pins 1 2 Write Protect via Software Control Default Pins 2 3 Write_Protect Enabled ME Mode Select Jumper Settings Jumper Setting Definition Pins 1 2 Manufacture s Mode Pins 2 3 Normal Default Manufacturer s Mode Jumper JPME2 allows the user to flash the system firmware from a host server in order to modify system settings Close this jumper to bypass ...

Page 43: ...n amber or off to indicate the speed of the connection See the table on the right for the functions associ ated with the connection speed LED JLAN1 2 LED Connection Speed Indicator LED Color Definition Off NC or 10 Mbps Green 100 Mbps Amber 1 Gbps Onboard Power LED LE1 An Onboard Power LED is located at LE1 This LED Indicator is lit when the system is on Be sure to unplug the power cable before re...

Page 44: ...set driver After accessing the ftp site go into the CDR_Images directory and locate the ISO file for your serverboard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Another option is to go to the Supermicro Website at http www supermicro com products Find the product page for your serverboard here where...

Page 45: ...sholds must be made within SuperDoctor III as the SuperDoctor III settings override the BIOS settings To set the BIOS temperature threshold settings again you would first need to uninstall SuperDoctor III Figure 5 6 SuperDoctor III Interface Display Screen Health Information 5 13 Onboard Battery Please handle used batteries carefully Do not damage the battery in any way a damaged battery may relea...

Page 46: ...5 34 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...

Page 47: ...em very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or mod...

Page 48: ...with an identical 8 cm 12 volt fan available from Supermicro p n FAN 0070L 2 Position the new fan into the space vacated by the failed fan previously re moved A click can be heard when the fan is fully installed in place and the power connections are made 3 If the system power is on the hot plug feature will cause the fan to start im mediately upon being connected to its header on the serverboard ...

Page 49: ...per airflow Warning Use caution when working around the backplane Do not touch the back plane with any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes which aid in proper airflow Figure 6 2 Removing System Cooling Fans 6 4 Drive Bay Installation Removal Accessing the Drive Bays SATA Drives You do not need to access the inside of the chassis or remove power to...

Page 50: ...ed into place with the rear exhaust fans Remove both of these fans by depressing their tabs and lifting them out of the chassis You can then lift the air shroud out see Figure 6 5 To reinstall simply position the air shroud in its proper place and push both fans back in until you hear them click into place Hard Drive Backplane The hard drives plug into a backplane that provides power drive ID and ...

Page 51: ...micro 1 First unplug the power cord from the failed power supply module 2 Depress the locking tab on the power supply module and use the handle to pull it straight out of the chassis 3 Replace the failed module with another by simply pushing the new power supply module into the power bay until you hear a click 4 Secure the locking tab on the unit and finish by plugging the AC power cord back into ...

Page 52: ...eatures dual JBOD expansion ports The Figure below illustrates the recommended expansion strategy JBOD attachment will vary de pending on the specific JBOD chassis that is being connected Please follow the instructions provided with the JBOD Figure 6 7 JBOD Expansion Port 2x JBOD OUT downstream ports JBOD OUT downstream port JBOD OUT downstream port JBOD IN upstream port JBOD IN upstream port ...

Page 53: ...6 12 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...

Page 54: ...e user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text message will accompany it The AMI BIOS has default text messages built in The manufacturer retains the option to include omit or change any of these text messages The AMI BIOS Setup utility uses a key based n...

Page 55: ...When you first enter the AMI BIOS Setup utility you will enter the Main setup screen You can always return to the Main setup screen by selecting the Main tab on the top of the screen The Main BIOS Setup screen is shown below Supermicro X9DR6 LN4 SMC Version This item displays the SMC version of the BIOS ROM used in this system SMC Build Date This item displays the date that the BIOS Setup utility ...

Page 56: ...es The options are Enabled and Disabled Power Button Function If this feature is set to Instant_Off the system will power off immediately as soon as the user presses the power button If this feature is set to 4_Second_Override the system will power off when the user presses the power button for 4 seconds or longer The options are Instant_Off and 4_Second_Override Restore on AC Power Loss Use this ...

Page 57: ...led L1 Data Prefetch Available when supported by the CPU Select Enabled to enable Level 1 data prefetch support to enhance system perfor mance For DP MP servers enable or disable this feature for system enhancement based on the specifications of the application running in the system at the time The options are Disabled and Enabled Intel Virtualization Technology Available when supported by the CPU...

Page 58: ...on power is main tained Chipset Configuration North Bridge Configuration This feature allows the user to configure the settings for the Intel North Bridge Intergraded IO Configuration Intel VT d Select Enabled to enable Intel Virtualization Technology support for Direct I O VT d by reporting the I O device assignments to the VMM Virtual Working Memory through the DMAR ACPI Tables This feature offe...

Page 59: ...5 0 0 2 0 dB P6 0 0 2 5 dB P7 6 0 3 5 dB P8 3 5 3 5 dB P9 0 0 3 5 dB and Auto Dn Rx Preset This feature allows the user to select a preset setting for a downstream compo nent receiver The options are P0 6 0 dB P1 7 0 dB P2 8 0 dB P3 9 0 dB P4 10 0 dB P5 11 0 dB P6 12 0 dB and Auto Up Tx Preset This feature allows the user to select the preset setting for a upstream component transmitter The option...

Page 60: ...emory for data backup When Lockstep is selected the motherboard uses two areas of memory to run the same set of operations in parallel The options are Independent Mirroring and Lockstep DDR Speed Use this feature to force a DDR3 memory module to run at a frequency other than what the system is specified in the specification The options are Auto Force DDR3 800 Force DDR3 1066 Force DDR3 1333 Force ...

Page 61: ... Controller 1 Controller 2 The options are Disabled and Enabled Legacy USB Support Available when USB Functions is not Disabled Select Enabled to support legacy USB devices Select Auto to disable legacy sup port if USB devices are not present Select Disable to have USB devices available for EFI Extensive Firmware Interface applications only The settings are Disabled Enabled and Auto Port 60 64 Emu...

Page 62: ...OM The options are Intel and LSI Device0 Device7 The AMI BIOS will automatically detect the onboard SAS devices and display the status of each SAS device as detected Thermal Configuration Thermal Management Select Enabled to initialize the PCH Thermal subsystem device located at D31 F6 The options are Enabled and Disabled ME SMBus Thermal Reporting Select Enabled to support ME SMBus System Managem...

Page 63: ...lect iSCSI to use the iSCSI Option ROM to boot the computer using a network device Select PXE Preboot Execution Environment to use an PXE Option ROM to boot the computer using a network device The options are iSCSI and PXE Load Onboard LAN1 Option ROM Load Onboard LAN2 Option ROM Load Onboard LAN3 Option ROM Load Onboard LAN4 Option ROM Select Enabled to enable the onboard LAN1 Option ROM LAN4 Opt...

Page 64: ...trol This feature allows the user to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop send ing data when the receiving buffer is full Send a Start signal to start sending data when the receiving buffer is empty The options are None Hardware RTS CTS and Software Xon Xoff VT UTF8 Combo Key Support Select Enabled to enable VT UTF8 ...

Page 65: ...chnology Feature Chipset TXT Trusted Execution Technology Feature Intel TXT LT SX Configuration This feature displays the following TXT configuration setting TXT LT SX Support This item indicated if the Intel TXT support is enabled or disabled Intel TXT LT SX Dependencies This feature displays the features that need to be enabled for the Intel Trusted Execution Technology to work properly in the s...

Page 66: ...Select Erase Immediately to immediately erase SMBIOS error event logs that ex ceed the limit when the SMBIOS event log is full Select Do Nothing for the system to do nothing when the SMBIOS event log is full The options are Do Nothing and Erase Immediately SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Disabled and Enabled MECI Mul...

Page 67: ...led Note After making changes on a setting be sure to reboot the system for the changes to take effect BMC Network Configuration LAN Channel 1 This feature allows the user to configure the settings for LAN1 Port Update IPMI LAN Configuration This feature allows the user to decide if the BIOS should configure the IPMI setting at next system boot The options are No and Yes If the option is set to Ye...

Page 68: ...connection Select UEFI to boot the system from the UEFI Built in EFI Shell The options are LAN Device UEFI Built in EFI Shell and Disabled Network Devices Delete Boot Options Delete Boot Option This item allows the user to select a boot device to delete from the boot priority list Select UEFI Built in EFI Shell to delete it from the boot priority list which will prevent system boot from the UEFI S...

Page 69: ...ore user s defaults click Yes to restore the user s defaults previously saved in the system or click No to abandon the user s defaults that were previously saved Boot Override This feature allows the user to enter a new setting to overwrite the original setting that was saved for the following devices LAN Device UEFI Built in EFI Shell Discard Changes and Exit Select this option to quit the BIOS S...

Page 70: ...7 32 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...

Page 71: ...ccurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error BIOS Error Beep Codes Beep Code LED Error Message Description 1 beep Refresh Circuits have been reset Ready to power up 5 short beeps 1 long beep Me...

Page 72: ...A 2 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...

Page 73: ...M sockets supporting up to 1 5 TB of LRDIMMs Load Reduced DIMMs 768 Gb of RDIMM Registered DIMMs or 128 GB of UDIMM Unbuffered UDIMMs ECC Non ECC DDR3 1866 1600 1333 1066 800 memory Note see Section 5 5 for details Drive Bays Sixteen hot swap drive bays to house SATA drives Peripheral Drive Bays One slim DVD ROM drive Expansion Slots Four PCI E 3 0 x16 slots one PCI E 3 0 x8 slot and one PCI E 3 0...

Page 74: ... 35º C 32º to 95º F Non operating Temperature 40º to 60º C 40º to 140º F Operating Relative Humidity 20 to 95 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 E...

Page 75: ... to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and a...

Reviews: