Sun Fire X4500/X4540 Server Service Manual • May 2010
2.4
Configuring BIOS Settings
This section describes how to view and modify the BIOS settings.
The Basic Input/Output System (BIOS) has a Setup utility stored in the BIOS flash
memory. The Setup utility reports system information and can be used to configure
the BIOS settings. The configured data is provided with context-sensitive Help and is
stored in the system's battery-backed CMOS RAM. If the configuration stored in the
CMOS RAM is invalid, the BIOS settings default to the original state specified at the
factory.
When the BIOS is started, the first BIOS Setup menu screen is displayed. The BIOS
Setup utility contains seven menu screens, which are displayed in this order: Main,
Advanced, PCI/PnP, Boot, Security, Chipset, and Exit.
■
Use the left and right arrow keys to move sequentially back and forth through the
seven screens (Fields that can be reconfigured are displayed in color. All other
fields are nonconfigurable.)
■
Use the up and down arrows, on the keyboard, to scroll through a menu.
■
Use the Tab key to move back and forth across columns.
2.4.1
Changing the Configuration of a BIOS Menu Item
You can change the BIOS configuration in several different interfaces:
■
Use a USB keyboard and mouse, and a VGA monitor connected directly to the
server.
■
Use the remote video console of the ILOM Service Processor and redirect the
server’s console output. See
Section B.4, “Redirecting Console Output” on
page B-3
.
■
Use a terminal (or terminal emulator connected to a computer) through the serial
port on the back panel of the server.
To change the system’s parameters:
1. Enter the BIOS Setup utility by pressing the F2 key while the system is
performing the power-on self-test (POST).
2. Highlight the field to be modified using the arrow and Tab keys.
3. Press Enter to select the field.
A dialog box appears. The box presents you with the options available for the
setup field that you have chosen.
Summary of Contents for 4540 - Phaser Copystation
Page 12: ...xii Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 34: ...1 20 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 196: ...3 76 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 210: ...B 12 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 219: ...Appendix C Status Indicator LEDs C 9 FIGURE C 5 Disk Drive and Fan Tray LEDs...
Page 250: ...E 6 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 256: ...G 4 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 264: ...Index 4 Sun Fire X4500 X4540 Server Service Manual May 2010...