Off: The DIMM is operating properly.
On (amber): The DIMM is faulty and must be replaced.
■
CPU fault LEDs on CPU0 or CPU1:
Off: The CPU is operating properly.
On (amber): The CPU is faulty and must be replaced.
■
The Battery fault LED:
Off: The battery is operating properly.
On (amber): The battery is faulty and must be replaced.
Note –
The CPU fault and DIMM LEDs continue to indicate a failure until the
system is powered up. The Battery LED continues to indicate a failure until the
service processor is started.
To replace the CPU:
1. Power off the server.
See
Section 3.7.1, “Powering Off the Server” on page 3-10
.
2. Remove the cable management arm.
See one of the following depending on your system:
■
Sun Fire X4500/X4540 Installation Guide
■
Sun X4500-J Slide Rail Installation Guide
(X4500)
■
“Early-Production Slide Rail and CMA Information” on page G-1
(X4500)
3. Remove the system controller.
See
“To Remove the System Controller (CRU)” on page 3-70
.
The CPUs are located inside the system controller.
Summary of Contents for 4540 - Phaser Copystation
Page 12: ...xii Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 34: ...1 20 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 196: ...3 76 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 210: ...B 12 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 219: ...Appendix C Status Indicator LEDs C 9 FIGURE C 5 Disk Drive and Fan Tray LEDs...
Page 250: ...E 6 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 256: ...G 4 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 264: ...Index 4 Sun Fire X4500 X4540 Server Service Manual May 2010...