Sun Fire X4500/X4540 Server Service Manual • May 2010
4. Identify which CPU module you are replacing, either CPU 0 or CPU 1.
The CPUs are labeled. See
FIGURE 3-23
(the X4500 system is shown).
FIGURE 3-23
CPU Board LED and Button Locations (X4500)
Figure Legend
1
Back of system
2
CPU 1 (under heat sink)
3
CPU 0 (under heat sink)
2
3
1