A-2
Sun Fire X4500/X4540 Server Service Manual • May 2010
TABLE A-5
contains the declared noise emissions in accordance with ISO 9296,
A-weighted, operating, and idling.
TABLE A-3
Sun Fire X4540 Server 110 VAC Power Specifications
Specification for X4540 at 110 VAC
Value
Universal AC Input
100-127VAC, 50/60Hz 12A
Heat output
Heat Output (max) 5800 BTU/hr (1700 W)
Heat Output (typ) 3753 BTU/hr (1100 W)
Input power (Sun Fire X4500)
200–240 VAC
Maximum input power
1700 WAC
TABLE A-4
Sun Fire X4500/X4540 Server Environmental Specifications
Specification
Value
Operating temperature
5˚ to 32 ˚C (41 ˚C to 90˚ F)
10% to 90% relative humidity, 27º C max. wet bulb
(noncondensing)
Storage temperature
-40 ˚C to 65 ˚C (-40 ˚F to 149 ˚F)
up to 93% relative humidity, noncondensing, 38 ºC max wet
bulb
Operating altitude
Up to 3048 meters, maximum ambient temperature is derated
by 1 º C per 300 meters above 900 meters
Nonoperating altitude
Up to 12,000 meters
TABLE A-5
Sun Fire X4500/X4540 Server Acoustic Noise Emission Specifications
Specification
28C and below
Above 28C
Acoustic noise
Less than 83 dB sound power in ambient temperature of up to 24º C
LwAd operating and
idle
8.0 B
8.5 B
LpAm
70 dB
75 dB
Summary of Contents for 4540 - Phaser Copystation
Page 12: ...xii Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 34: ...1 20 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 196: ...3 76 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 210: ...B 12 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 219: ...Appendix C Status Indicator LEDs C 9 FIGURE C 5 Disk Drive and Fan Tray LEDs...
Page 250: ...E 6 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 256: ...G 4 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 264: ...Index 4 Sun Fire X4500 X4540 Server Service Manual May 2010...