Chapter 3
Maintaining the Sun Fire X4500 and X4540 Servers
3-45
▼
To Replace a Battery (CRU)
Note –
This component is a CRU and can be replaced by anyone.
Follow these steps to remove and replace the system battery.
TABLE 3-13
lists the qualified part number for this component. These part numbers are
subject to change over time. For an updated list of components, see the following
web site:
http://sunsolve.sun.com/handbook_pub/Systems/
1. Power off the server as described in
Section 3.7.1, “Powering Off the Server” on
page 3-10
.
2. Remove the cable management arm.
See one of the following depending on your system:
■
Sun Cable Management Assembly Installation Guide for the Sun Fire X4540 Server
■
Sun X4500-J Slide Rail Installation Guide
(X4500)
■
“Early-Production Slide Rail and CMA Information” on page G-1
(X4500)
3. Remove the system controller as described in
“To Remove the System Controller
(CRU)” on page 3-70
.
TABLE 3-13
Sun Fire X4540/X4540 Supported Battery Part Numbers
Component
Part Number
Battery (X4500, X4540)
#150-3993
Summary of Contents for 4540 - Phaser Copystation
Page 12: ...xii Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 34: ...1 20 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 196: ...3 76 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 210: ...B 12 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 219: ...Appendix C Status Indicator LEDs C 9 FIGURE C 5 Disk Drive and Fan Tray LEDs...
Page 250: ...E 6 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 256: ...G 4 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 264: ...Index 4 Sun Fire X4500 X4540 Server Service Manual May 2010...