3-32
Sun Fire X4500/X4540 Server Service Manual • May 2010
*—See
Sun Fire X4500-to-X4540 Migration User’s Guide
(820-6559).
For a list of compatible SSDs, see
“Replacing a Solid-State Drive (Sun Fire X4540
CRU)” on page 3-35
.
Note –
Before removing a drive, have the replacement drive ready to be installed.
For supported solid-state drives and their part numbers, see
“Replacing a Solid-State
Drive (Sun Fire X4540 CRU)” on page 35
.
Caution –
To avoid overheating the server, if the server is powered on, do not leave
a disk drive out for longer than 60 seconds at a time. Remove and replace only one
disk drive at a time. Replace the disk drive access cover as soon as the service tasks
are completed. Before removing a drive, have the replacement drive ready to be
installed.
Note –
Early fan trays had a blue LED that was not activated. Later versions of the
fan trays have only a green and amber LED.
1. Remove the drives access cover.
See
“To Remove the Drives Access Cover” on page 3-13
.
2. Identify the drive to be removed by checking its LEDs.
If the middle LED is on (amber), the drive is faulty and should be replaced.
TABLE 3-11
Disk Drives for the X4540 Server
Disk Drive
Part Number
Seagate 250GB/7200RPM, SATA 3.5” drive (X4540)
#541-1468,
XRA-ST1CH-250G7KZ (X-option)
Seagate 250GB/7200RPM, SATA, 3.5” (X4540)
#541-3678,
XRA-ST1CH-250G7KZ (X-option)
Seagate 500GB, SATA, 3.5” (X4540)
#541-3679
Seagate 1TB SATA, 3.5” (X4540)
#541-3730
Hitachi 500GB/7200RPM, SATA, 3.5” (X4540)
#541-3050,
XRA-ST1CH-500G7KZ (X-option)
Hitachi 1TB/7200RPM, SATA, 3.5” (X4500, X4540)
#540-7507,
XRA-ST1CH-1T7K
Hitachi 2TB/7200RPM, SATA, 3.5” (X4500, X4540)
#541-4241
Summary of Contents for 4540 - Phaser Copystation
Page 12: ...xii Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 34: ...1 20 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 196: ...3 76 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 210: ...B 12 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 219: ...Appendix C Status Indicator LEDs C 9 FIGURE C 5 Disk Drive and Fan Tray LEDs...
Page 250: ...E 6 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 256: ...G 4 Sun Fire X4500 X4540 Server Service Manual May 2010...
Page 264: ...Index 4 Sun Fire X4500 X4540 Server Service Manual May 2010...