Operation
Option 2:
Do not turn the tyre over on the rim
•
Press the
FINE
key (
3
).
The result is recalculated.
Reading
OP.7 - II
or
H0
or
H2
appears
•
To go to
II - OP.7
(turning over the tyre) press the
FINE
key (
3
) again.
Option 3:
Abort optimisation
•
Press the
STOP
key (
5
) to exit the OP program and
return to the balancing program.
The imbalance on the wheel is shown on the readout.
•
Balance the wheel according to the readings.
Reading
OP.7 - II
(
Fig. 5-37
)
Readjust the tyre on the rim (the right display bars light
up permanently).
Option 1:
Readjust the tyre on the rim
(normal program)
•
Readjust the wheel following the right direction
indicator and make a double mark on the right side
of the tyre exactly perpendicular to and above the
main shaft
(
Fig. 5-38
)
.
•
Remove the wheel from the machine
•
Readjust the tyre on the rim until the double mark
coincides with the valve
(
Fig. 5-39
)
.
•
Clamp the wheel on the balancer and readjust so
that the valve is exactly perpendicular to and above
the main shaft.
•
Press the
ENTER
key
(
1
)
to acquire the valve
position.
Reading
OP.8
appears
(
Fig. 5-34
)
.
•
Spinn the wheel
(START
) (check run).
If balancing optimisation (silent running) has been
carried out correctly according to the program cycle,
after the check run the machine automatically returns to
the type of weight positioning previously selected and
indicates the residual dynamic imbalance on the wheel.
•
Balance the wheel according to the readings.
Both optimisation and balancing are accomplished.
Message
E9
Message E9 means that at least one error occurred
during the optimisation cycle. Press the
STOP
key
(
5
) to exit the optimisation program and repeat
optimisation if necessary.
Option 2:
do not adjust the tyre on the rim
•
Press the
STOP
key (
5
) to exit the OP program and
return to the balancing program.
The imbalance on the wheel is shown on the readout.
•
Balance the wheel according to the readings.
Reading
H0
•
Press the
STOP
key (
5
) to exit the OP program and
return to the balancing program.
The imbalance on the wheel is shown on the readout.
•
Balance the wheel according to the readings.