Chapter 8
Troubleshooting the Sun StorEdge T3+ Array Devices
105
Sun Proprietary/Confidential: Internal Use Only
volume
State
Change-
Red
Y
1. Open a Telnet session
to the affected Sun
StorEdge T3+ array.
2. Verify the status of the
LUNs with
vol_mode
or
vol
_stat
.
Drive Status Messages:
0 Drive mounted
2 Drive present
3 Drive is spun up
4 Drive is disabled
5 Drive has been
replaced
7 Invalid system area on
drive
9 Drive not present
D Drive disabled; is
being reconstructed
S Drive substituted
power
State
Change-
Red
Y
The Sun StorEdge T3+
array has reported that a
power cooling unit has
been disabled.
A PCU failure can
happen due to:
1. Power loss
2. The PCU fails
3. The power switch is
disrupted.
1. Check the power
supply and cables.
2. Replace PCU, if
necessary.
enclosure
Statistics
Displays statistics about
the Sun StorEdge T3+
array enclosure
TABLE 8-1
Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array
Component
Event
T
ype
Se
verity
Action
Description
Action