Chapter 8
Troubleshooting the Sun StorEdge T3+ Array Devices
99
Sun Proprietary/Confidential: Internal Use Only
enclosure
Audit
Auditing a new Sun
StorEdge T3+ array
Audits occur every week.
The Storage Automated
Diagnostic Environment
sends a detailed
description of the
enclosure to the Sun
Network Storage
Command Center
(NSCC).
ib
Comm_
Established
Communication regained
InBand (ib)
oob
Comm_
Established
Communication regained
oob (OutOfBand)
ib
Comm_Lost
Down
Y
Since InBand (ib)
monitoring is established
using
luxadm,
the
monitoring may not be
activated for a particular
Sun StorEdge T3+ array.
1. Verify
luxadm
with
the command line
(
luxadm
probe,
luxadm
display)
2. Verify cables, GBICs,
and connections along
the data path.
3. Check the Storage
Automated Diagnostic
Environment SAN
Topology GUI to
identify the failing
segment of the data
path.
4. Verify the correct FC
switch configuration,
if applicable.
TABLE 8-1
Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array
Component
Event
T
ype
Se
verity
Action
Description
Action