100
Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
oob
Comm_Lost
Down
Y
OutOfBand (oob) means
that the Sun StorEdge
T3+ array failed to
answer to a ping or failed
to return its tokens.
This OutOfBand problem
can be caused by a very
slow network, or because
the Ethernet connection
to this Sun StorEdge T3+
array was lost.
1. Check the Ethernet
connectivity to the
affected Sun StorEdge
T3+ array.
2. Verify that the Sun
StorEdge T3+ array is
booted correctly.
3. Verify the correct
TCP/IP settings on
the Sun StorEdge T3+
array .
4. Increase the http
timeout.
5. Ping timeout in
Utilities
->System
->System
->Timeouts
.
The current default
timeouts are 10 seconds
for ping and 60 seconds
for
http
(tokens).
t3ofdg
Diagnostic
Test-
Red
The t3ofdg
(1M) test
failed.
t3test
Diagnostic
Test-
Red
The
t3test
(1M) test
failed.
t3volverify
Diagnostic
Test-
Red
The t3volverify
(1M)
test failed.
TABLE 8-1
Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array
Component
Event
T
ype
Se
verity
Action
Description
Action