Appendix A
Virtualization Engine References
159
Sun Proprietary/Confidential: Internal Use Only
SRN/SNMP Single Point-of-Failure
Descriptions
TABLE A-2
provides Simple Network Management Protocol (SNMP) descriptions,
associated Service Request Numbers (SRNs), and recommendations for corrective
action.
TABLE A-2
SRN/SNMP Single Point-of-Failure Table
SRN
SNMP Description
Corrective Action
SRN after
Corrective
Action
70020
70021
70030
70050*
• The SAN topology has changed.
• The Global SAN configuration has
changed.
• The SAN configuration has
changed.
• A physical device is missing.
• Check the SAN cabling and
connections between the Sun
StorEdge T3+ array andthe
virtualization engine.
• Perform Sun StorEdge T3+ array
failback, if necessary.
70020
70030
70051**
70025
The IP of the partner’s virtualization
engine is not reachable.
Check the Ethernet cabling and
connections.
None
72000
72007
70020
70021
70022
70025
70030
70050
• The SAN topology has changed.
• The Global SAN configuration has
changed.
• The SAN configuration has
changed.
• The IP of the partner virtualization
engine is not reachable.
• A physical device is missing.
• A
SLIC
virtualization engine is
missing.
• A
SLIC
daemon connection is
inactive.
• The virtualization engine failed to
check for SAN changes, or a daemon
error occurred.
• A secondary daemon connection is
active.
• Check cabling and connections
between the virtualization engines.
• Cycle power on failed
virtualization engine, if the fault LED
flashes.
• Perform Sun StorEdge T3+ array
failback, if necessary.
• Enable VERITAS path.
• Check the SLIC virtualization
engine.
70020
70021
70022
70024*
70030
70050
* Sun StorEdge T3+ array LUN failover.
** Sun StorEdge T3+ array LUN failback.