46
Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
An error in the A1 or B1 FC link can also cause a device to enter the “unusable” state
in
cfgadm -al
, as shown in
CODE EXAMPLE 5-2
.
CODE EXAMPLE 5-2
cfgadm -al
Display
FRU Tests Available for the A1 or B1 FC Link
Segment
The following FRU tests are available for the A1 or B1 FC link segment. All
diagnostics are located in
/opt/SUNWstade/Diags/bin
. Refer to the man pages
for more details.
■
HBA—
qlctest
(1M)
■
Available only if the Storage Automated Diagnostic Environment is installed
on a data host
■
Causes HBA to go offline and online during tests
■
Switch —
switchtest
(1M)
■
Can be run while the link is still cabled and online (connected to HBA)
■
Can be run only from the Storage Service Processor.
■
The
dev
option to
switchtest
is in the following format:
Port:IP-Address:FCAddress
The
FCAddress
can be set to 0x0.
Note –
If you are testing an A1 or B1 FC link that is connected to an HBA, you must
specify a payload of 200 bytes or less. This is a limitation in the HBA application-
specific integrated circuit (ASIC).
# /usr/sbin/cfgadm -al
Ap_Id
Type
Receptacle
Occupant
Condition
c0
scsi-bus
connected
configured
unknown
c0::dsk/c0t0d0
disk
connected
configured
unknown
c0::dsk/c0t1d0
disk
connected
configured
unknown
c1
scsi-bus
connected
configured
unknown
c1::dsk/c1t6d0
CD-ROM
connected
configured
unknown
c2
fc-fabric
connected
configured
unknown
c2::210100e08b23fa25
unknown
connected
unconfigured unknown
c2::2b000060220041f4
disk
connected
configured
unknown
c3
fc-fabric
connected
configured
unknown
c3::2b000060220041f9
disk
connected
configured
unusable
c4
fc-private
connected
unconfigured unknown
c5
fc
connected
unconfigured unknown