Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
Common to Sun
StorEdge T3+ array
• The Sun StorEdge T3+ array is not
of T3B type, so it aborts operations.
•
t3config
utilities are supported
only in the Sun StorEdge T3+ array;
the
t3config
utilities are not
supported on Sun StorEdge T3+
arrays with 1.xx firmware.
1. Refer to the T3 default/custom
configuration table in the Sun
StorEdge 3900 and 6900 Series 2.0
Reference and Service Guide.
2. Use
showt3-n t3_name
to
display the present configuration.
3. Check the Sun StorEdge T3+
firmware version (it should be
version 2.01.00 or higher).
Upgrade if required.
Common to Sun
StorEdge T3+ array
• No response received from
$t3_name
. Aborting operation.
1. Check the Sun StorEdge T3+
network connection.
2. Check with Ping
$t3_name
command to determine if the Sun
StorEdge T3+ array is operating.
Common to Sun
StorEdge T3+ array
volslice
is not enabled on this Sun
StorEdge T3+ array.
Check the T3+ firmware (2.01.00 or
higher) to make sure volume slicing
is allowed with this version of
firmware.
Common to Sun
StorEdge T3+ array
• Error while opening the Sun
StorEdge T3+ array.
• Cannot open after resetting the Sun
StorEdge T3+ array.
1. Check the Sun StorEdge T3+
master and alternate master
network connection.
2. Check with Ping
$t3_name
command to determine if the Sun
StorEdge T3+ array is operating.
checkt3config
The
vol init
command is being
executed by another user. Additional
vol
commands cannot run.
1. Check whether any other
secfg
utility is running.
2. If an
secfg
utility is running,
allow it to finish.
checkt3config
An error occurred while the
checkt3config
command was
checking the process list, causing the
t3_name
to abort.
Check whether any other
secfg T3+
or native Sun StorEdge
T3+ array commands are being
executed on that particular Sun
StorEdge T3+ array.
checkt3config
Snapshot configuration files are not
present. Unable to check
configuration.
1. Verify that the snapshot files are
saved and have read permissions
in the
/opt/SUNWsecfg/etc/t3name
/
directory.
2. If the snapshot files are not
available, create them using the
savet3config
command.
TABLE B-3
Sun StorEdge T3+ Array Error Messages (Continued)
Source of Error Message
Cause of Error Message
Suggested Corrective Action