Appendix A
Virtualization Engine References
161
Sun Proprietary/Confidential: Internal Use Only
050
An attempt to write a value into
nonvolatile storage failed,
perhaps because a hardware
failure, or one of the databases
stored in Flash memory could
not accept the entry being
added.
• Clear the SAN database.
• Cycle power to the
virtualization engine.
051
The virtualization engine cannot
erase Flash memory.
• Replace the virtualization
engine.
53
The cabling configuration is
unauthorized.
• Check the cabling. Ensure the
server and switch connect to the
host side and the storage
connects to the device side of the
virtualization engine.
• If necessary, clear the SAN
database.
• If necessary, cycle the
virtualization engine power.
• If necessary, import the SAN
zone configuration.
54
The cabling configuration is
unauthorized.
• Check the cabling.
57
Too many HBAs are attempting
to log in.
• Check the cabling.
60
The node mapping table was
cleared using
SW2
.
• No action required.
62
SW2
settings are incorrect..
• Correct the
SW2
setting.
• Cycle the virtualization engine
power.
126
Too many virtualization engines
in the SAN.
• Remove the extra
virtualization engine.
• Cycle the virtualization engine
power.
130
The connection between
virtualization engines is down.
• Correct the problem.
• Cycle the power on the
follower virtualization engine.
TABLE A-4
Virtualization Engine Service Codes (Continued)—0 -399 Host-Side Interface Driver Errors