Appendix B
Configuration Utility Error Messages
171
Sun Proprietary/Confidential: Internal Use Only
Sun StorEdge T3+ Array Partner Group
Error Messages
Caution –
Running
restoret3config
(1M) or
modifyt3config
(1M) destroys all
data on the Sun StorEdge T3+ array
.
TABLE B-3
Sun StorEdge T3+ Array Error Messages
Source of Error Message
Cause of Error Message
Suggested Corrective Action
Common to Sun
StorEdge T3+ array
• The current configuration does not
match the reference (standard)
configurations.
• This particular configuration is not
a standard, supported type.
1. Check the current Sun StorEdge
T3+ array configuration with the
showt3 -n <t3>
command.
2. Verify whether the configuration
is corrupted or has changed.
3. Refer to the
raid.cfg
files in
/opt/SUNWsecfg/etc
to
determine if the configuration
commands are set up and
functioning properly.
Common to Sun
StorEdge T3+ array
• Could not mount volume
$vol
ume
•
$lun
config does not match
• The LUN might have multiple
drive failures or corrupted data or
parity.
1. Replace the failed FRUs.
2. Restore the Sun StorEdge T3+
array configuration with the
restoret3config -f -n
t3_name
command.
Common to Sun
StorEdge T3+ array
• No volumes exist on this Sun
StorEdge T3+ array.
•
$volume volume
not found on
this Sun StorEdge T3+ array.
Create and restore the Sun StorEdge
T3+ array LUNs using
restoret3config
(1M) or
modifyt3config
(1M).
Common to Sun
StorEdge T3+ array
• The
$fru
status is not ready or
enabled.
• Operations on the Sun StorEdge
T3+ array are being aborted.
The disk, controller, or loop interface
card in the Sun StorEdge T3+ array
might be faulty. Replace the failed
FRU and rerun the utility.