118
Netra ct Server Installation Guide • September 2002
3. Set up the serial port communications parameters.
The default settings should match the values reported on the host serial port.
■
Hardwired modem connection
■
No parity
■
9600 baud
■
1 stop bit
■
8 bit data
4. Test the connection.
Verify that communication has been established to the server and the keyboard/
display of the ASCII terminal.
▼
To Use a Solaris Workstation
1. Get the appropriate cable(s) and adapter(s) and make the necessary connections.
You may need one or more cables and adapters in order to connect a Solaris
workstation to the server. The cables and adapters you need varies, depending on
the model server you have and the card that you are connecting to.
■
If you are connecting a Solaris workstation to a CPU or CPU transition card, use
the information in
TABLE 7-3
to make the necessary connections.
■
If you are connecting a Solaris workstation to an alarm card or alarm rear transition
card, use the information in
TABLE 7-4
to make the necessary connections.