Chapter 5: Maintaining the Server
5-10
User Guide—Sun Cobalt LX50 Server
Air Baffle
The air baffle must be removed before you can replace the fan module.
Removal
1.
Before removing the cover to work inside the system, observe the safety guidelines mentioned earlier.
2.
Remove the chassis cover.
3.
As shown in Figure 68, gently spread the air baffle walls at (B) and (C) and lift up until pin (A) is free of the
board mounting hole.
4.
Remove the baffle from the chassis.
Figure 68.
Removing the Air Baffle
Installation
1.
Ensure the flex cable, auxiliary power cable, and SCSI cables are routed under where you will be installing the
air baffle.
2.
Aligning pin (A) with the board mounting hole, position the air baffle over the white server board power
connector.
3.
Lower the baffle into position and press it down against the chassis floor.
4.
Ensure tabs (B) and (C) are under the edge of the server board.
!
Caution
: Before touching or replacing any component inside the LX50 server, disconnect all
external cables and follow the instructions in “Safety: Before You Remove the Cover” on
page 5-2 and “Removing and Replacing the Cover” on page 5-3. Always place the server on a
grounded ESD pad and wear a properly grounded antistatic wrist strap.
OM11704
A
B
C
A
Summary of Contents for Cobalt LX50
Page 1: ...Sun Cobalt LX50 Server User Guide...
Page 10: ...Contents x User Guide Sun Cobalt LX50 Server...
Page 14: ...xiv User Guide Sun Cobalt LX50 Server...
Page 22: ...Chapter 1 Introducing the Sun Cobalt LX50 server 1 8 User Guide Sun Cobalt LX50 Server...
Page 58: ...Chapter 3 Controls and Indicators 3 4 User Guide Sun Cobalt LX50 Server...
Page 114: ...Chapter 5 Maintaining the Server 5 30 User Guide Sun Cobalt LX50 Server...
Page 132: ...Chapter 6 Troubleshooting the Server 6 18 User Guide Sun Cobalt LX50 Server...