Installing the Server Using the Bracket Kit
User Guide—Sun Cobalt LX50 Server
2-15
Front-Mount-Only in a Two-Post Rack System
Remove the Chassis Handles
1.
Remove the bezel.
2.
Remove two screws from each handle (see Figure 14).
3.
Set the handles and screws aside for reattachment later.
Figure 14.
Removing a Handle from the Chassis
Warning:
Your chassis rack-mount kit provides the option for mounting the system in a
two-post front-mount-only configuration. However, mounting your chassis using this option is
not recommended for use in most rack systems. In fact, the front mount method is highly
discouraged, as most racks are unable to safely and reliably support the entire weight of a
server through the front rack posts
If a front-mount-only configuration is desired, it is highly recommended that you verify
through your rack vendor that your specific rack is designed to support the excessive weight
and stresses this type of mounting configuration imposes on the rack. Structural failure of the
rack is likely if it is not designed for this type of load. A four-post or a two-post mid-mount
configuration should be used when possible.
Summary of Contents for Cobalt LX50
Page 1: ...Sun Cobalt LX50 Server User Guide...
Page 10: ...Contents x User Guide Sun Cobalt LX50 Server...
Page 14: ...xiv User Guide Sun Cobalt LX50 Server...
Page 22: ...Chapter 1 Introducing the Sun Cobalt LX50 server 1 8 User Guide Sun Cobalt LX50 Server...
Page 58: ...Chapter 3 Controls and Indicators 3 4 User Guide Sun Cobalt LX50 Server...
Page 114: ...Chapter 5 Maintaining the Server 5 30 User Guide Sun Cobalt LX50 Server...
Page 132: ...Chapter 6 Troubleshooting the Server 6 18 User Guide Sun Cobalt LX50 Server...