Section 6
SUPERVISOR II
25
6.1 INTRODUCTION--SUPERVISOR II
Ref er t o
F igur e 6 -- 1
and S ec t ion 5 f or inf or m at ion r e-
garding your compressor with Supervisor II. The
Supervisor II has a two line display to show temper-
ature, pressure and status. It has a keypad for oper-
ating the compressor, programming the control
points and selecting displays. There is a graphic il-
lustration with lamps that light to show the item be-
ing displayed. The lamps flash if that component is
in an alarm condition.
6.2 KEYPAD
The keypad is used to control the machine as well as
dis play s t at us and c hange s et point s . Ref er t o
F
igur e
6 -- 1
f or f ollowing k ey des c r ipt ions .
S
Stop
-- Used to put the machine into manu-
al stop. It is also used to clear alarm condi-
tions.
O
S
Continuous
-- Starts machine if no alarm
conditions are present. Also used to clear
alarm conditions while machine is running.
I
S
Auto
-- Starts machine and selects auto
mode if no alarm conditions are present.
Also used to clear alarm conditions while
machine is running.
S
Display
-- Used to display pressures, tem-
peratures and other status information (See
section on STATUS DISPLAYS).
DSP
S
Logo
-- Used for various functions de-
scribed in later sections
S
Program
-- Used to enter the parameter
change mode where control parameters
may be displayed and changed (See PA-
RAMETER SETUP).
PRG
S
Up arrow
-- Used in status displays to
change displays and in parameter setup
mode to increment a value.
S
Down arrow, lamp test
-- Used in status
displays to change displays and in parame-
ter setup mode to increment a value. When
in the default display the key will light all the
lamps for three seconds.
6.3 STATUS DISPLAYS
By default the line pressure (P2) and discharge tem-
perature (T1) are shown on the bottom line of the
display, and machine status on the top line.
The following are the various machine status mes-
sages that indicate the state of the compressor with
LCD graphics listed below:
S
STOP
-- Compressor is off.
S
STANDBY
-- Compressor is off but armed
to start. This state may be entered because
of a power up, or the unload timer had ex-
pired and stopped the machine. NOTE :
The machine may start at any time.
S
STARTING
-- Machine is trying to start.
S
OFF LOAD
-- Machine is running and off
loaded.
S
ON LOAD
-- Machine is running and
loaded.
S
FULL LD
-- Machine is running and fully
loaded. This state is only displayed if the
machine has a full load valve and under se-
quence control.
S
RMT STOP
-- Compressor is off but armed
to start. The machine will start when the re-
mote start contact is closed. NOTE : the
machine may start at any time.
S
SEQ STOP
-- Compressor is off but armed
to start. The machine will start when the se-
quencing conditions meet the criteria to
start. NOTE : the machine may start at any
time.
This default display appears as follows:
Summary of Contents for ES-11 SERIES
Page 6: ...NOTES...
Page 13: ...Section 2 INSTALLATION 7 Figure 2 1 Service Air Piping...
Page 14: ...8 NOTES...
Page 18: ...Section 4 COMPRESSOR SYSTEMS 12 Figure 4 1A Description of Components...
Page 19: ...Section 4 COMPRESSOR SYSTEMS 13 AIR COOLED WATER COOLED Figure 4 1B Description of Components...
Page 22: ...Section 4 COMPRESSOR SYSTEMS 16 Figure 4 3 Pneumatic Control System Standard Supervisor II...
Page 30: ...24 NOTES...
Page 34: ...28 NOTES...
Page 40: ...Section 7 MAINTENANCE 34 Figure 7 6 Cooler Cleaning COOLER SHROUD COMPRESSOR ENCLOSURE COOLER...
Page 42: ...36 NOTES...
Page 48: ...42 NOTES...
Page 50: ...Section 9 ILLUSTRATIONS AND PARTS LIST 44 9 3 FRAME MOTOR COMPRESSOR AND PARTS...
Page 52: ...Section 9 ILLUSTRATIONS AND PARTS LIST 46 9 4 COMPRESSOR AND PARTS 44...
Page 54: ...Section 9 ILLUSTRATIONS AND PARTS LIST 48 9 4 COMPRESSOR AND PARTS 44...
Page 56: ...Section 9 ILLUSTRATIONS AND PARTS LIST 50 9 5 MOTOR AND PARTS...
Page 60: ...Section 9 ILLUSTRATIONS AND PARTS LIST 54 9 7 COOLING SYSTEM AND PARTS AIR COOLED...
Page 62: ...Section 9 ILLUSTRATIONS AND PARTS LIST 56 9 7 COOLING SYSTEM AND PARTS AIR COOLED...
Page 64: ...Section 9 ILLUSTRATIONS AND PARTS LIST 58 9 8 COOLING SYSTEM AND PARTS WATER COOLED...
Page 66: ...Section 9 ILLUSTRATIONS AND PARTS LIST 60 9 8 COOLING SYSTEM AND PARTS WATER COOLED...
Page 68: ...Section 9 ILLUSTRATIONS AND PARTS LIST 62 9 8 COOLING SYSTEM AND PARTS WATER COOLED...
Page 70: ...Section 9 ILLUSTRATIONS AND PARTS LIST 64 9 9 CONTROL BOX AND PARTS STANDARD NOTE...
Page 72: ...Section 9 ILLUSTRATIONS AND PARTS LIST 66 9 9 CONTROL BOX AND PARTS STANDARD NOTE...
Page 74: ...Section 9 ILLUSTRATIONS AND PARTS LIST 68 9 9 CONTROL BOX AND PARTS STANDARD NOTE...
Page 76: ...Section 9 ILLUSTRATIONS AND PARTS LIST 70 9 9A CONTROL BOX AND PARTS SUPERVISOR II NOTE...
Page 78: ...Section 9 ILLUSTRATIONS AND PARTS LIST 72 9 9A CONTROL BOX AND PARTS SUPERVISOR II NOTE...
Page 80: ...Section 9 ILLUSTRATIONS AND PARTS LIST 74 9 9B CONTROL PANEL AND PARTS ELECTRO MECHANICAL...
Page 82: ...Section 9 ILLUSTRATIONS AND PARTS LIST 76 9 10 CANOPY ACOUSTICAL PANELS AND PARTS...
Page 84: ...Section 9 ILLUSTRATIONS AND PARTS LIST 78 9 10 CANOPY ACOUSTICAL PANELS PARTS...
Page 86: ...Section 9 ILLUSTRATIONS AND PARTS LIST 80 9 11 DECAL GROUP 1 2 3 4 5 6 02250077 472 2A...
Page 88: ...Section 9 ILLUSTRATIONS AND PARTS LIST 82 9 11 DECAL GROUP 8 9 10 11 12 13 7...
Page 91: ...Section 9 ILLUSTRATIONS AND PARTS LIST 85 9 13 WIRING DIAGRAM FULL VOLTAGE SUPERVISOR II...
Page 93: ...Section 9 ILLUSTRATIONS AND PARTS LIST 87 9 15 WIRING DIAGRAM WYE DELTA 50 60 HZ SUPERVISOR II...
Page 97: ...NOTES...