REMOVE DRIVE UNIT ASSEMBLY FROM CASE
'
o t
K
i
V
),567
Make certain you have all the correct parts and fasteners necessary for correct installation. Re-use any
components that are not damaged, otherwise replace them. Parts used in this process: (3) AEC1224 Hex Nuts,
(3) AEC1238 Lock Washers, (2) AEC1819 Flange Fork Connectors, (2) AEC1830 Insulated Connectors,
(1) AEC1813 White Wire, (1) AEC1842 Black Wire, (1) AEC1841 White Wire, and (1) AEC1813 Green or Green/
<
ellow Wire.Plus any components required to correctly reinstall the Sub-Top and Top Assemblies (Page 17).
REMOVE DRIVE UNIT ASSEMBLY
1) Remove SUITMATE
®
unit from the Wall Mount Bracket. See instructions beginning on Page 14.
2) Remove Top and Sub-Top Assemblies. See instructions beginning on Page 15.
3) Place the SUITMATE
®
on its face to expose the bottom of the unit.
4) Unscrew the (2) captive screws that secure the Motor end cap from the bottom of the Motor.
5) Remove the end cap with captive screws and set it aside for reassembly.
6) Remove the Micro Switch Box Cover. The cover is held on with (2) Machine Screws. Remove cover and
screws and set aside for reassembly.
7) Disconnect the (4) wires connecting the motor to the unit by disconnecting the wires from the L1 and L2
terminals on the Motor. Loosen the Green Grounding screw and disconnect the green or green/yellow
ground wire.
Note:
On units without a Timer, there are (3) wires.
8) Cut off the (4) wire connectors from the wires to allow the wires to be pulled through the 90
o
conduit connector.
9) Pull the wires through the 90
o
conduit connector by pulling them from the Micro Switch Box about
2 to 3 inches.
10) Remove the 90
o
conduit connector from the Motor by disconnecting the plastic cable conduit from the
90
o
conduit connector and unscrewing the 90
o
conduit connector from the Motor.
11) Return the SUITMATE
®
unit to its upright position.
12) Remove the three sets of Hex Nuts and Lock Washers that hold the Drive Unit to the Case. Set them aside
for reassembly.
13) From the top of the SUITMATE
®
unit, grasp the sides of the Basket. Remove the Drive Unit by lifting the
Drive Unit up at a slight angle.
Note:
%
e careful not to damage the
%
lack Plastic
/
iner. If the
/
iner is damaged, it must be replaced.
REPLACE DRIVE UNIT ASSEMBLY
1) Align the (3) Shock Mounts on the Drive Unit with the (3) holes in the Case and lower the Drive Unit into
the Case making certain that the (3) Shock Mounts are in the appropriate holes in the Case, so that the 90
o
connector will be in the correct position. See the Bottom View diagram of the SUITMATE
®
unit on Page 22.
Note:
%
e careful not to damage the
%
lack Plastic
/
iner. If the
/
iner is damaged, it must be replaced.
2) Replace the (3) sets of Hex Nuts and Lock Washers on the Shock Mount threaded inserts that protrude
through the Case.
3) Replace the 90
o
conduit connector by screwing it into the Motor.
Note:
%
e careful not to cross thread the threads on the
0
o
conduit connector.
4) Reconnect the plastic cable conduit to the 90
o
conduit connector.
5) Push the (4) wires from the Micro Switch Box up into the Motor.
Note:
On units without a Timer, there are (3) wires.
6) Strip the (4) wires enough to install the NEW appropriate wire connectors on the wires.
7) Reattach the (4) wire connectors to the appropriate terminals in the Motor: Green or Green/
<
ellow Wire to
green screw, (2) White Wires to terminal L2 (one Insulated and one Flange Fork), and Black Wire to terminal L1.
8) Reinstall the Motor end cap with the (2) captive screws removed in step 5 above.
9) Reinstall the Sub-Top and Top Assemblies. See instructions beginning on Page 17.
10) Reinstall the SUITMATE
®
unit to the Wall Mount Bracket. See instructions beginning on Page 14.
11) Retest the SUITMATE
®
unit for proper operation, refer to TESTING AND OPERATION on Page 7.