S-CB
+
Boiler Range Manual
36
Examples D and E maximum pipe lengths
Example D
boiler type
S-CB
+
60 S-CB
+
80
S-CB
+
100
S-CB
+
120
S-CB
+
150
S-CB
+
180
Diameter concentric pipe
[mm]
80/125
80/125
100/150
100/150
NOT
RECOMMENDED
(choose B,C or E)
Concentric roof terminal
[mm]
80/125
80/125
100/150
100/150
Maximum pipe length
[m]
13,5
6,0
12,0
7,5
Example E
boiler type
S-CB
+
60 S-CB
+
80
S-CB
+
100
S-CB
+
120
S-CB
+
150
S-CB
+
180
Diameter concentric pipe
[mm]
80/125
80/125
100/150
100/150
100/150
100/150
Concentric wall terminal
[mm]
80/125
80/125
100/150
100/150
100/150
100/150
Maximum pipe length
[m]
18,5
12,5
19,0
14,0
7,0
4,0
concentric roof
terminal
concentric wall
terminal
Example D
Example E