125
BOILER
HEATING
ZONE
SIGNAL FOR CONTROLLING P3: 230 VAC.
A RELAY NEEDS TO BE ADDED TO SWITCH PUMP3 (P3)
SYSTEM 4
Table for system 4:
SYSTEM 5
Table for system 5
Code Name
Wire terminal
Part nr.
P1
Boiler pump
Relay pump1
P3
System pump
34-36
(230 Vac control signal)
OH
Low loss header
-
RT
Modulating room unit with
timer
13-14
OS
Outside temperature sensor
E04.016.585
FS
External flow sensor
03-04
E04.016.304
PARAMETER CHANGE:
NO
Code
Name
Wire terminal
Part nr.
P1
Boiler pump
Relay pump1
P2
Calorifier primary pump
38-40 (230 Vac control signal)
P3
System pump
34-36 (230 Vac control signal)
OH
Low loss header
-
T
Calorifier
-
NRV
Non-return valve
-
RT
Modulating room unit with timer
13-14
OS
Outside temperature sensor
01-02
E04.016.585
FS
External flow sensor
03-04
E04.016.304
ST
Tank sensor
05-06
E400277
PARAMETER CHANGE:
NO
BOILER
HEATING
ZONE
SIGNAL FOR CONTROLLING P2: 230 VAC.
A RELAY NEEDS TO BE ADDED TO SWITCH PUMP2 (P2)
SIGNAL FOR CONTROLLING P3: 230 VAC. A RELAY
NEEDS TO BE ADDED TO SWITCH PUMP3 (P3)