2.5.4 Stoddart Standard Filter
IMPORTANT
This oven must be installed in accordance with AS/NZS 3500.1
The Oven must be installed with the supplied Dual Check Valve,
Water Filter and Pressure Limiting Valves
• Water connections are labelled on the oven
• Isolation valve must be installed at the water
supply outlet
• Water Temperature:
Cold water connection - Min 10°C, Max 35°C
• Steam Generation:
The Combi oven requires filtered water supplied
to its steam generation system. Water pressure
must be 150-350 kPa at oven connection. This is
controlled with the supplied PLV
• Wash System:
The Combi oven requires unfiltered water supplied
to its wash system.
Water pressure must be 150-350 kPa at oven
connection. This is controlled with the supplied
PLV
• Refer to the Stoddart Standard Filter user manual
for filter setup
Supplied Components
(Plumbing Kit / Water Filter Kit)
A. 1 x Stoddart Standard Filter
B. 1 x Dual Check Valve
C. 1 x 4 Way Manifold
D. 3 x 3/4” BSP To 3/8” Tube Connector
E. 1 x 1/2” BSP To 3/8” Tube Connector
F. 2 x 3/8” John Guest Stem Elbow
G. 2 x Pressure Limiting Valve
300-350
Kpa
H. 1 x Nipple, 3/4” Male
I. 1 x 3m 3/8 Tube (Water)
J. 12 x John Guest Locking Clip
K. Spare outlet
2.0 Installation