background image

199 Series

Rev. 3

/

99

USER
MANUAL
FOR THE
METRO
C199 AND
FL199
SERIES
INSULATED
HEATED
CABINETS

Recommended Food Holding
Guidelines Listed on pages 5 & 6.

®

®

InterMetro Industries Corporation

Wilkes-Barre, PA 18705
570-825-2741

Summary of Contents for C199 Series

Page 1: ...es Rev 3 99 USER MANUAL FOR THE METRO C199 AND FL199 SERIES INSULATED HEATED CABINETS Recommended Food Holding Guidelines Listed on pages 5 6 InterMetro Industries Corporation Wilkes Barre PA 18705 570 825 2741 ...

Page 2: ...ment Cabinet Model No ________________________ Module Model No _________________________ Module Serial No _________________________ Slide Rack Model No ______________________ SAMPLE OF CABINET LABELING C199 HM2000 Full Height Holding C199T HM2000 3 4 Height Holding OR FL199 HM2000 Full Height High Humidity Holding FL199H HM2000 1 2 Height High Humidity Holding SAMPLE OF SLIDE RACK CARTON LABELING ...

Page 3: ...ush with top of the cabinet mounted hinge part Invert the door latch by removing black plastic screw covers and remove the screws holding the latch in place 6 On double door units rotate the top door 180 degrees and mount in the position of the lower door Rotate what was the bottom door 180 degrees and mount in the position of the top door Align the door mounted hinge part with the cabinet mounted...

Page 4: ...is designed to maintain the temperature of HOT prepared foods The holding module is equipped with a thermostatically controlled heater a blower for air circulation and a water pan A POWER switch is provided with a red light to indicate when the unit is switched ON Beside the POWER switch is the TEMPERATURE thermostat and its yellow indicator light A seven foot three wire grounded lead cord is supp...

Page 5: ...emperature in the cabinet The temperature setting can be adjusted by turning the temperature knob clockwise to increase and counter clockwise to decrease temperature 5 The humidity can be adjusted by turning the humidity knob clockwise to increase and counter clockwise to decrease humidity If you wish to hold food without using humidity turn the Humidity control to MIN This will prevent the cabine...

Page 6: ...sconnect valve Empty the water bottle and rinse replace the bottle into the cabinet and refill with clean cold water The cabinet is now ready to use III FOOD HOLDING GUIDELINES A FL2000 Recommended Food Holding Guidelines Food Product Covered Uncovered Temperature Setting F Moisture Setting Baked Fish Uncovered 175 Med High Baked Potatoes Uncovered 180 Off Biscuit Uncovered 180 Medium Broccoli Cov...

Page 7: ... Fried Fish Uncovered 180 Hamburgers Covered 180 Lasagna Covered 185 Mashed Potatoes Covered 175 Mixed Veggies Covered 170 175 Pancakes Covered 175 Pasta Covered 180 Peas Covered 170 175 Pizza Uncovered 175 180 Roast Beef Uncovered 170 180 Roast Pork Uncovered 170 180 Scalloped Potatoes Covered 175 Strip Steak Uncovered 160 170 Turkey Uncovered 170 180 Waffles Covered 175 Whole Chicken Uncovered 1...

Page 8: ...utine daily cleaning is practiced a mild soap and warm water should be sufficient to keep the unit clean 2 HEAVIER SOIL If cleaning has been postponed solvent or emulsion type cleaners that can be applied with bare hands will give excellent results Such cleaners are available under various brand names and detergent suppliers can recommend materials appropriate for use on natural and epoxy coated a...

Page 9: ...VI REPLACEMENT PARTS PROCEDURES AND WIRING DIAGRAMS A CABINET ALL MODELS Refer to the Cabinet Replacement Parts Diagram on next page to identify the replacement parts C199 Series Cabinet Replacement Parts Diagram see page 9 for parts list ...

Page 10: ...4SC T Rack 3 4 height cabinet 12 C4SC H C4SC H Rack 1 2 height cabinet 13 C8SN C8SN Rack full height cabinet 14 C8SN T C8SN T Rack 3 4 height cabinet 15 C8SN H C8SN H Rack 1 2 height cabinet 16 CVSN CVSN Rack full height cabinet 17 CVSN T CVSN T Rack 3 4 height cabinet 18 CVSN H CVSN H Rack 1 2 height cabinet 19 RPC175 1108 Chimney full height cabinet 20 RPC199H 1108 Chimney 1 2 height cabinet 21 ...

Page 11: ...E TO A POWER SOURCE PRACTICE EXTREME CAUTION SO AS NOT TO RECEIVE ELECTRICAL SHOCK FROM EXPOSED COMPONENTS 2 Refer to the appropriate Module Replacement Parts Diagram to identify the internal components Determine malfunctioning component s by electrical diagnostic procedures 3 After servicing be sure to verify the routing of each wire with the wiring schematic before installing electrical cover an...

Page 12: ...ating Blower 9 RPC13 114 Heat Element Units with 15 Amp Plug 9 RPC13 093 Heat Element Units with 20 Amp Plug 10 RPC13 064 Red Indicator Light 11 RPC13 181 Thermometer 12 RPC13 096 Terminal Block Control Panel 13 RPC13 012 Ring Terminal 14 RPF02 042 Push Nut Indicator Lights 15 RPC11 191 Blower Collar 16 RPC13 085 Wire Nuts 12 GA 17 RPC07 044 Grommet Thermometer Wire 18 RPC06 222 Thermostat Thermom...

Page 13: ...12 HOLDING WIRING DIAGRAM VI WIRING SCHEMATICS ...

Page 14: ...Blower 10 RPC13 166 Heat Element 11 RPC09 117 Humidity Generator 12 RPC13 167 Band Heater 13 RPC13 168 Humidity Cut out Switch 14 RPFL 3 8TUBE Tubing 15 RPC13 096 Terminal Block 16 RPHHM WBA Water Bottle 17 RPC15 024 Coupling 18 RPFL20 RMS Rear Seal 19 RPFL20 SMS Side Seal 20 RPC13 134 Hi Temp Cut out 21 RPC13 172 Percentage Timer 22 RPC13 129A Thermostat 23 RPC13 173 Relay 24 RPC13 174 Transforme...

Page 15: ...Y SENSOR THERMOSTAT HEAT TIMER PERCENTAGE 24VAC LOAD RED BLUE YELLOW WHITE BLACK BLACK BLACK WHITE WHITE SWITCH CUT OUT HI TEMPERATURE ELEMENT WHITE BLACK BUZZER BLOWER DUCT ELEMENT SWITCH CUT OUT HI TEMPERATURE STEAMER STEAMER ELEMENT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 19 20 23 24 13 15 16 17 18 1 POWER SWITCH LEAD CORD 7 10 12 GREEN GROUND TERMINAL BLOCK THERMOMETER S...

Page 16: ...l No Slide Rack Model No Date Purchased Customer Name Address Phone No For warranty coverage this card must be returned to Metro 2 Please indicate the two product benefits that were of major interest to you a Accessibility to controls without opening door b All components within cabinet removable for cleaning c Better control of conditions in cabinet d Uniform environment within cabinet due to for...

Page 17: ...ERE BUSINESS REPLY MAIL FIRST CLASS PERMIT NO 121 WILKES BARRE PA NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES POSTAGE WILL BE PAID BY INTERMETRO INDUSTRIES CORPORATION ATTN CUSTOMER SERVICE P O BOX A WILKES BARRE PA 18705 9968 STAPLE HERE ...

Page 18: ...ller are solely the warranties of the manufacturers thereof and they are hereby assigned to the purchaser without recourse to the Seller SELLER S LIABILITY FOR ANY CLAIM OF ANY KIND WHETHER BASED ON CONTRACT NEGLIGENCE OR STRICT LIABILITY IN TORT AND BY WHOMEVER MADE FOR ANY DIRECT INDIRECT INCIDENTAL OR CONSEQUENTIAL LOSS DAMAGE OR INJURY RESULTING TO THE PURCHASER OR ANY THIRD PARTIES arising ou...

Page 19: ...th Washington Street Wilkes Barre PA 18705 For Product Information Call 1 800 433 2232 Visit Our Web Site www metro com L01 386 Rev A 03 03 Information and specifications are subject to change without notice Please confirm at time of order ...