Page 38
Due to continuous product research and development,
the information contained herein is subject to change without notice.
www.stoddart.com.au
www.stoddart.co.nz
SET
PUSH
C
B
SET
PUSH
C
B
A
A
4.3.10 Setting Moisture Percentage for Combi Mode
4.3.11 Steam Tuner Function
Only in “Combi” mode can the percentage of humidity for the oven to maintain during cooking can be set. With the patented Meteo System
(humidity control), the relative humidity in the cooking chamber is measured, humidity is added or removed, to maintain the settings
programmed by the operator.
The level of hydration of the steam can be set in “Steam” mode using the patented SteamTuner control. The setting must be made according
to the product being cooked and the result you wish to obtain.
To set the amount of hydration of the steam, press humidity field and set the value. If the default value is not set, it is “normal”.
To set moisture percentage:
A. Touch the Humidity field
B. Turn the navigation dial to adjust the
percentage value
C. Press the navigation dial to save the
set value
To adjust level of hydration:
A. Touch the Hydration field
B. Turn the navigation dial to adjust the
percentage value
C. Press the navigation dial to save the
set value
Type of cooking
Humidity input
Humidity extraction
Combi
adjustable from 0% to
100%
the oven opens and
closes the flue vent
automatically
Type of cooking
Humidity input
Humidity extraction
Steam
flue vent always
closed
4.0 Operation